Abstract
The development and application of a flow-through amperometric biosensor for benzydamine determination in anti-inflammatory drugs is described. The biosensor was obtained by physical entrapment of monoamine oxidase in a sol-gel film applied on platinum or carbon paste conducting support. The sol-gel membranes were prepared using an optimum concentration of 3-aminopropyltriethoxy silane, 2-(3,4-epoxycyclohexyl)ethyl-trimethoxy silane, double distilled water saturated with polyethylene glycol 6000 and HCl. The developed biosensors were incorporated in a single channel flow injection system to enable the determination of benzydamine in the concentration range of 0.05-2.5 mmol l(-1) (with platinum based electrode) or within 0.1-2.5 mmol l(-1) (carbon paste based electrode). The operational stability of the bioanalytical system developed was about 3 months permitting approximately 4700 substrate measurements. The flow injection system developed enables a sampling rate of 20-25 samples h(-1) and relative S.D. of results less than 4%. The analytical usefulness of the proposed procedure was evaluated through analysis of commercial pharmaceutical products containing benzydamine, available on the Portuguese market. The results obtained did not differ significantly from the values resulting from analysis of the same products by the method described in the BP Pharmacopoeia.
Similar articles
-
Application of lactate amperometric sol-gel biosensor to sequential injection determination of L-lactate.J Pharm Biomed Anal. 2007 Mar 12;43(4):1376-81. doi: 10.1016/j.jpba.2006.11.027. Epub 2007 Jan 4. J Pharm Biomed Anal. 2007. PMID: 17207600
-
Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode.Talanta. 2017 May 1;166:420-427. doi: 10.1016/j.talanta.2015.11.072. Epub 2015 Nov 30. Talanta. 2017. PMID: 28213255
-
Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode.Anal Biochem. 2004 Oct 1;333(1):49-56. doi: 10.1016/j.ab.2004.06.039. Anal Biochem. 2004. PMID: 15351279
-
Sol-gel-based biosensing applied to medicinal science.Curr Top Med Chem. 2015;15(3):245-55. doi: 10.2174/1568026614666141229113012. Curr Top Med Chem. 2015. PMID: 25547971 Review.
-
Flow injection analysis with immobilized reagents.Curr Opin Biotechnol. 1991 Feb;2(1):9-16. doi: 10.1016/0958-1669(91)90055-a. Curr Opin Biotechnol. 1991. PMID: 1367714 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources