[Efficacy of intravenous myocardial contrast echocardiography for assessment of perfusion area of the heart in mice]
- PMID: 14658410
[Efficacy of intravenous myocardial contrast echocardiography for assessment of perfusion area of the heart in mice]
Abstract
Background and objectives: Intravenous myocardial contrast echocardiography is used clinically, but use in small animals has not been evaluated. The conditions for myocardial opacification and the feasibility of myocardial contrast echocardiography were examined in mice.
Methods: Closed chest mice were examined. The left ventricular short-axis view at the mid papillary muscle level was recorded before and after NC100100 injection using a SONOS 5500 (PHILIPS). Real time and intermittent triggering (every 5 beats) myocardial contrast echocardiography was performed with a mechanical index of low (0.3), middle (0.7), and high (1.5). Open chest mice were examined after left anterior descending coronary artery ligation. Myocardial contrast echocardiography was performed using intermittent triggering imaging (every 5 beats) with high mechanical index (1.5). The ratio of the non-perfused area to the whole left ventricular wall area was compared with that of the non-stained area by Evans Blue.
Results: The left ventricular myocardium was opacified in any setting. Good opacification was acquired at middle mechanical index (0.7) in real time myocardial contrast echocardiography and at high mechanical index (1.5) in intermittent myocardial contrast echocardiography. The opacified and non-opacified myocardium were clearly identified in all mice with coronary ligation. The non-opacified area ratio showed a good correlation with the non-stained area ratio (y = 0.93x + 0.51, r = 0.94, p < 0.05).
Conclusions: Myocardial contrast echocardiography can be used to assess myocardial perfusion and determine the ischemic area accurately in situ in the mouse.
Similar articles
-
[Optimal setting of focus points for myocardial contrast echocardiography with intravenous Optison (FS-69): an experimental study].J Cardiol. 2001 Apr;37(4):201-7. J Cardiol. 2001. PMID: 11337929 Japanese.
-
[Usefulness of intravenous myocardial contrast echocardiography in rats].J Cardiol. 2001 Apr;37(4):209-14. J Cardiol. 2001. PMID: 11337930 Japanese.
-
Multi-focus setting improves the heterogeneity of myocardial opacification in intravenous contrast echocardiography.J Cardiol. 2002 Jul;40(1):11-7. J Cardiol. 2002. PMID: 12166244
-
[Intravenous contrast echocardiography].J Cardiol. 2000 Mar;35 Suppl 1:23-9. J Cardiol. 2000. PMID: 10834166 Review. Japanese.
-
[Intravenous myocardial contrast echocardiography; recent advances].Rinsho Byori. 2003 Oct;51(10):1018-22. Rinsho Byori. 2003. PMID: 14653202 Review. Japanese.
Cited by
-
Monocrotaline-induced pulmonary hypertension with sufficient tricuspid regurgitation in a rat model.J Med Ultrason (2001). 2012 Oct;39(4):221-6. doi: 10.1007/s10396-012-0371-x. Epub 2012 May 24. J Med Ultrason (2001). 2012. PMID: 27279108