A strategy for metabolite identification using triple-quadrupole mass spectrometry with enhanced resolution and accurate mass capability
- PMID: 14673820
- DOI: 10.1002/rcm.1256
A strategy for metabolite identification using triple-quadrupole mass spectrometry with enhanced resolution and accurate mass capability
Abstract
Using a single platform of a triple-quadrupole mass spectrometer equipped with enhanced resolution and accurate mass capabilities, a strategy for metabolite identification of a drug in a biological matrix has been demonstrated. The strategy is based on first screening for metabolites via neutral loss and precursor ion scan schemes, devised as the result of the product ion spectrum of a matrix-free standard of the drug. The accurate masses of the precursor ions identified via the two scan schemes plus the precursor ions of structurally likely metabolites are then determined by enhanced resolution, accurate mass (AM) selected ion monitoring (SIM). The identities of the metabolites are further established by determining the accurate masses of the product ions via enhanced resolution AM selected reaction monitoring (SRM). The feasibility of the strategy was demonstrated using a liver microsome incubation sample of nefazodone, an antidepressant drug. The neutral loss and precursor ion screening runs were able to identify most of the metabolites of nefazodone. The subsequent SIM and SRM experiments gave mass accuracy of better than +/-0.003 u for the masses of the precursor and product ions of nefazodone and all the metabolites. The ability to perform metabolite screening by using the scan features followed by accurate mass determinations on the same instrument is an attractive feature of using a triple-quadrupole mass spectrometer with enhanced resolution and accurate mass capability.
Copyright 2003 John Wiley & Sons, Ltd.
Similar articles
-
Enhanced resolution triple-quadrupole mass spectrometry for fast quantitative bioanalysis using liquid chromatography/tandem mass spectrometry: investigations of parameters that affect ruggedness.Rapid Commun Mass Spectrom. 2003;17(1):24-38. doi: 10.1002/rcm.872. Rapid Commun Mass Spectrom. 2003. PMID: 12478552
-
'N-in-one' strategy for metabolite identification using a liquid chromatography/hybrid triple quadrupole linear ion trap instrument using multiple dependent product ion scans triggered with full mass scan.Rapid Commun Mass Spectrom. 2007;21(8):1421-30. doi: 10.1002/rcm.2976. Rapid Commun Mass Spectrom. 2007. PMID: 17377936
-
Development of a simple and reliable accurate mass liquid chromatography/electrospray ionization mass spectrometry method for high-resolution accurate mass determinations of new drug entities on a triple quadrupole mass spectrometer.Rapid Commun Mass Spectrom. 2007;21(18):3051-9. doi: 10.1002/rcm.3188. Rapid Commun Mass Spectrom. 2007. PMID: 17705256
-
Options for veterinary drug analysis using mass spectrometry.J Chromatogr A. 2009 Nov 13;1216(46):8016-34. doi: 10.1016/j.chroma.2009.07.007. Epub 2009 Jul 14. J Chromatogr A. 2009. PMID: 19665721 Review.
-
Strategies for characterization of drug metabolites using liquid chromatography-tandem mass spectrometry in conjunction with chemical derivatization and on-line H/D exchange approaches.J Pharm Biomed Anal. 2005 Feb 7;37(1):1-18. doi: 10.1016/j.jpba.2004.09.003. J Pharm Biomed Anal. 2005. PMID: 15664738 Review.
Cited by
-
Metabolomics and proteomics annotate therapeutic properties of geniposide: targeting and regulating multiple perturbed pathways.PLoS One. 2013 Aug 15;8(8):e71403. doi: 10.1371/journal.pone.0071403. eCollection 2013. PLoS One. 2013. PMID: 23967205 Free PMC article.
-
Recent trends in mass spectrometer development.Anal Bioanal Chem. 2004 Feb;378(4):845-50. doi: 10.1007/s00216-003-2287-1. Epub 2003 Nov 4. Anal Bioanal Chem. 2004. PMID: 14598011 Free PMC article.
-
Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers.Front Chem. 2021 Dec 21;9:813359. doi: 10.3389/fchem.2021.813359. eCollection 2021. Front Chem. 2021. PMID: 34993180 Free PMC article. Review.
-
Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: examination of the human liver microsomal metabolism of the non-tricyclic anti-depressant nefazodone using data-dependent accurate mass measurements.J Am Soc Mass Spectrom. 2006 Mar;17(3):363-75. doi: 10.1016/j.jasms.2005.11.014. Epub 2006 Jan 25. J Am Soc Mass Spectrom. 2006. PMID: 16442304
Publication types
MeSH terms
Substances
LinkOut - more resources