Chiral separation with ligand-exchange micellar electrokinetic chromatography using a D-penicillamine-copper(II) ternary complex as chiral selector
- PMID: 14679569
- DOI: 10.1002/elps.200305610
Chiral separation with ligand-exchange micellar electrokinetic chromatography using a D-penicillamine-copper(II) ternary complex as chiral selector
Abstract
D-Penicillamine is demonstrated for the first time as a chiral ligand for the enantioseparation of dansyl amino acids based on ligand-exchange micellar electrokinetic chromatography (LE-MEKC). Copper(II) was used as the central ion in the ternary complex. The effect of surfactant on the resolution was significant. A concentration of 20 mM sodium dodecyl sulfate (SDS) was shown to be necessary for the separation. Other important parameters, such as the concentration ratio of D-penicillamine (D-PEN) to Cu2+, the kind of metal central ion, the type and pH value of buffer, were also investigated. N-Acetyl-D-penicillamine and L-valine (Val), with similar structure to D-penicillamine, were applied as their copper(II) complexes as chiral selector and the chiral recognition mechanism is briefly discussed. Under optimum experimental conditions, i.e., 20 mM NH4OAc, pH 6.5, a 2:1 concentration ratio of D-penicillamine to Cu(II), 4 mM CuSO4 and 8 mM D-penicillamine, the chiral separation of eight pairs of different dansyl amino acid enantiomers was accomplished with resolution ranging from 1.1 to 5.9. When L-PEN was used instead of D-PEN, reversal of the migration order was observed.
Similar articles
-
Chiral separation of dansyl-DL-amino acids with micellar systems containing copper (II) ion and N-n-dodecyl-L-proline in electrokinetic capillary chromatography.Electrophoresis. 1999 Sep;20(13):2761-5. doi: 10.1002/(SICI)1522-2683(19990901)20:13<2761::AID-ELPS2761>3.0.CO;2-S. Electrophoresis. 1999. PMID: 10532345
-
Chiral separation of underivatized and dansyl amino acids by ligand-exchange micellar electrokinetic capillary chromatography using a copper(II)-L-valine complex as selector.J Chromatogr A. 2003 Jul 25;1007(1-2):189-96. doi: 10.1016/s0021-9673(03)00960-9. J Chromatogr A. 2003. PMID: 12924564
-
Chiral separation and determination of amino acids in real samples by LE-MEKC using Cu(II)-L-proline as chiral selector.J Chromatogr B Analyt Technol Biomed Life Sci. 2014 Aug 15;965:254-9. doi: 10.1016/j.jchromb.2014.07.001. Epub 2014 Jul 11. J Chromatogr B Analyt Technol Biomed Life Sci. 2014. PMID: 25062477
-
Chiral electrokinetic chromatography using dipeptide polymeric surfactants: present state of the art.Electrophoresis. 1999 Oct;20(15-16):3011-26. doi: 10.1002/(SICI)1522-2683(19991001)20:15/16<3011::AID-ELPS3011>3.0.CO;2-#. Electrophoresis. 1999. PMID: 10596813 Review.
-
Differentiation of enantiomers by capillary electrophoresis.Top Curr Chem. 2013;340:209-75. doi: 10.1007/128_2013_438. Top Curr Chem. 2013. PMID: 23666080 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources