Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004;18(1):117-27.
doi: 10.1002/rcm.1286.

N-t-butyliodoacetamide and iodoacetanilide: two new cysteine alkylating reagents for relative quantitation of proteins

Affiliations

N-t-butyliodoacetamide and iodoacetanilide: two new cysteine alkylating reagents for relative quantitation of proteins

Carla Pasquarello et al. Rapid Commun Mass Spectrom. 2004.

Abstract

The synthesis and application of two new alkylating reagents, N-tert-butyl-2-iodoacetamide (N-t-butyliodoacetamide) and 2-iodo-N-phenylacetamide (iodoacetanilide), are described. N-t-Butyliodoacetamide and iodoacetanilide were synthesised to purity in their d(0)-light and in their respective d(9)- and d(5)-heavy forms. The newly synthesised reagents are covalently bound to peptides containing cysteines via an alkylation reaction. The mass differences of 5 and 9 Da avoid possible problems of overlapping isotope distribution. For each alkylated cysteine a peptide mass increases, respectively, by a multiple of 113 and 133 Da for the d(0)-light form of N-t-butyliodoacetamide and iodoacetanilide. These reagents can therefore replace common alkylating reagents in existing proteomics-based applications. Alkylated peptides increase in mass in the same mass range as amino acids and remain suitable for tandem mass spectrometry (MS/MS) data acquisition and analysis. The compounds are simple to use and derivatisation is based on widely applied alkylating procedures. Preliminary results show that these reagents can be applied for both protein quantitation and identification by peptide mass finger printing and/or MS/MS techniques. Using these chemicals and the suggested workflow enables the quantitative analysis of the whole protein sample and realises access to peptides that may contain potential post-translational modifications. Other approaches that incorporate a matrix-assisted laser desorption/ionisation (MALDI) interface prior to MS can take advantage of these chemicals, such as the molecular scanner.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources