Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Dec;20(6):730-2.
doi: 10.1093/fampra/cmg618.

Comparison of blood pressure measurements on the bare arm, below a rolled-up sleeve, or over a sleeve

Affiliations
Clinical Trial

Comparison of blood pressure measurements on the bare arm, below a rolled-up sleeve, or over a sleeve

Ernesto Kahan et al. Fam Pract. 2003 Dec.

Abstract

Background: This study examined the effect of measuring blood pressure below subjects' rolled-up sleeves, over the sleeve, or on the bare arm. This is an important day-to-day issue for the busy GP.

Methods: The sample consisted of 201 subjects in family practice clinics and residents of a senior citizens' home. A digital device was used in all cases. Each participant underwent three blood pressure measurements in each of the following conditions in random order: cuff on bare arm; cuff over the sleeve; and cuff below the rolled-up sleeve. Differences between measurements were plotted against the mean blood pressure. Confounding factors controlled for were age, sex, clothing pressure and skin-fold thickness.

Results: Differences in mean blood pressure readings between the clothed and bare arm were 0.5 mmHg (SD 7.5) for systolic pressure and 1 mmHg (SD 5) for diastolic pressure; neither difference was significant. However, in hypertensive subjects (>140 mmHg systolic), although the mean difference remained small (systolic pressure, 2 mmHg, SD 10), the range of difference for individual subjects was -32 mmHg to +22 mmHg.

Conclusion: The degree of clothing under the sphygmomanometer cuff does not have a clinically important effect on the blood pressure measurement. In patients known or found to be hypertensive, measurement on the bare arm is recommended.