Reliability of perception of fever by touch
- PMID: 14703224
- DOI: 10.1007/BF02730588
Reliability of perception of fever by touch
Abstract
Objective: To assess the reliability of touch to predict fever in children.
Methods: 200 children who reported with fever formed the study material. Group I consisted of 100 children between 0-1 year of age and Group II consisted of 100 children between 6-12 years of age. Preterm, neonates under warming device, tachypnoeic and hypothermic were excluded from the study. The caregiver (CG) and the medical staffs (MS) response regarding presence or absence of fever by touch was noted in each child. Both were blinded to each other's response. Immediately temperature was recorded by calibrated rectal thermometer in Group I and calibrated axillary thermometer in Group II.
Results: The CG's touch had a sensitivity of 70.5% specificity of 40.9%, PPV of 38% NPV of 72.9%, PLR was 1.16 and NLR was 0.75. The MS's touch had a sensitivity of 78.0%, specificity of 63.6%, PPV of 38.0% NPV 84.8%, PLR of 2.08 and NLR of 0.36. There is over and under diagnosis of fever by both, the former being more by the CG reflecting the parental anxiety. The MS's touch is better to affirm or negative fever as compared to CG. The best site to palpate for presence of fever was abdomen, neck and forehead.
Conclusion: Touch is not a valid screening test for fever. It is recommended that a thermometer must always be used by the MS to record fever and CG must be motivated for the same.
Similar articles
-
Validity and accuracy of maternal tactile assessment for fever in under-five children in north central Nigeria: a cross-sectional study.BMJ Open. 2014 Oct 10;4(10):e005776. doi: 10.1136/bmjopen-2014-005776. BMJ Open. 2014. PMID: 25304190 Free PMC article.
-
Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever.Afr J Med Med Sci. 1997 Sep-Dec;26(3-4):163-6. Afr J Med Med Sci. 1997. PMID: 10456161
-
Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes.BMC Pediatr. 2018 Jan 26;18(1):15. doi: 10.1186/s12887-018-0994-1. BMC Pediatr. 2018. PMID: 29373961 Free PMC article.
-
The accuracy and reliability of the tympanic membrane thermometer. A literature review.Emerg Nurse. 2001 Feb;8(9):13-7. doi: 10.7748/en2001.02.8.9.13.c1347. Emerg Nurse. 2001. PMID: 11935722 Review. No abstract available.
-
Managing the child with a fever.Practitioner. 2015 Jul-Aug;259(1784):17-21, 2-3. Practitioner. 2015. PMID: 26514056 Review.
Cited by
-
Acceptance of temporal artery thermometry by Nigerian mothers: a comparison with the traditional methods.Pan Afr Med J. 2014 Nov 11;19:263. doi: 10.11604/pamj.2014.19.263.2899. eCollection 2014. Pan Afr Med J. 2014. PMID: 25852806 Free PMC article.
-
Thermometry in children.J Emerg Trauma Shock. 2012 Jul;5(3):246-9. doi: 10.4103/0974-2700.99699. J Emerg Trauma Shock. 2012. PMID: 22988404 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Medical