Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Jan;103(1):148-56.
doi: 10.1097/01.AOG.0000109220.24211.BD.

False-positive 1-hour glucose challenge test and adverse perinatal outcomes

Affiliations
Comparative Study

False-positive 1-hour glucose challenge test and adverse perinatal outcomes

David M Stamilio et al. Obstet Gynecol. 2004 Jan.

Abstract

Objective: To determine whether a false-positive 1-hour glucose challenge test (GCT) is associated with perinatal complications.

Methods: We performed a retrospective cohort study of 1825 eligible pregnant women among a cohort of 1998 patients. Patients were screened for gestational diabetes mellitus (GDM) with the 1-hour 50-g GCT at 24-28 gestational weeks. A false-positive GCT was defined as a result greater than or equal to 135 mg/dL followed by a normal 3-hour glucose tolerance test (GTT). We compared the negative GCT and false-positive GCT cohorts for a composite perinatal outcome variable that included fetal macrosomia, antenatal death, shoulder dystocia, chorioamnionitis, preeclampsia, intensive care nursery admission, and postpartum endometritis. Secondary outcomes included cesarean delivery and each component variable of the composite. Unadjusted, stratified, and multiple logistic regression analyses were used to investigate the association between a false-positive GCT and the development of perinatal complications.

Results: We identified 164 patients with a false-positive GCT and 50 patients with GDM. The false-positive GCT cohort on average was older, of higher parity, had a higher body mass index, and more frequently had chronic hypertension, sickle cell trait, and elevated midtrimester human chorionic gonadotropin levels. The false-positive GCT cohort more frequently had adverse perinatal outcomes, including the composite perinatal outcome (odds ratio [OR] 5.96, 95% confidence interval[CI]1.47,24.16), macrosomia greater than 4500 g (OR 3.66, 95% CI 1.30, 10.32), antenatal death (OR 4.61, 95% CI 0.77, 27.48), shoulder dystocia (OR 2.85, 95% CI 1.25, 6.51), endometritis (OR 2.18, 95% CI 1.03, 4.63), and cesarean delivery (OR 1.76, 95% CI 0.99, 3.14).

Conclusion: A false-positive GCT is an independent risk factor for adverse perinatal outcomes.

PubMed Disclaimer

Publication types