Investigation of TRAM flap oxygenation and perfusion by near-infrared reflection spectroscopy and color-coded duplex sonography
- PMID: 14707632
- DOI: 10.1097/01.PRS.0000095940.96294.A5
Investigation of TRAM flap oxygenation and perfusion by near-infrared reflection spectroscopy and color-coded duplex sonography
Abstract
Near-infrared reflection spectroscopy, used experimentally for investigation of tissue hemoglobin content and oxygenation in various flaps, was tested in the pedicled transverse rectus abdominis musculocutaneous (TRAM) flap, chosen as a simple clinical model because of its well-known vascular anatomy and clinical relevance. The study intended to answer the following questions: Does the near-infrared reflection spectroscopy system used in this study measure tissue hemoglobin content and oxygenation in the superficial skin layers only, as proposed by the manufacturer? Is near-infrared reflection spectroscopy able to detect differences of tissue hemoglobin content and oxygenation in distinct zones of the TRAM flap skin before, early, and late after surgery? Does tissue hemoglobin content and oxygenation correspond to blood flow in the supplying superior epigastric artery and to clinical signs of TRAM flap perfusion and viability? In 11 patients, tissue hemoglobin content and oxygenation in the lower abdomen/TRAM flap, mastectomy skin flap, and contralateral breast were measured by a new near-infrared reflection spectroscopy system preoperatively, early postoperatively, and late postoperatively. Simultaneously, systolic peak flow in the ipsilateral superior epigastric artery was obtained by color-coded duplex sonography. Routine clinical monitoring was performed throughout the early postoperative period. Tissue hemoglobin content and oxygenation in the lower abdomen, mastectomy skin flap, and contralateral breast were similar before surgery but varied considerably between different patients. There were no significant differences among preoperative, early postoperative, and late postoperative values of tissue hemoglobin content and oxygenation in the mastectomy skin flap and contralateral breast. However, near-infrared reflection spectroscopy measurements of the TRAM flap revealed significant differences between preoperative and early postoperative values of tissue hemoglobin content and oxygenation and among zones I, II, and III early after surgery. Tissue hemoglobin content in the TRAM flap skin increased and oxygenation decreased early after surgery. Near-infrared reflection spectroscopy values corresponded to clinical signs of venous congestion predominantly in zone III. Late postoperative return of hemoglobin content and oxygenation in the TRAM flap toward preoperative values can be attributed to improved venous return by reversed flow across regurgitant valves and development of collateral circulation. Finally, there was a significant increase of systolic peak flow in the ipsilateral superior epigastric artery early after surgery. This could be related to the opening of small-caliber choke arteries between the superior and deep inferior epigastric arteries following ligation of the dominant deep inferior epigastric artery and TRAM flap transfer to the chest. Systolic peak flow returned to preoperative values late after surgery. The near-infrared reflection spectroscopy system used in this study appeared to measure hemoglobin content and oxygenation in the superficial skin layers only. Near-infrared reflection spectroscopy was able to detect differences of tissue hemoglobin content and oxygenation in the TRAM flap between preoperative and postoperative measurements and between distinct zones of the TRAM flap early postoperatively. Postoperative changes in near-infrared reflection spectroscopy values corresponded to clinical observations and blood flow in the superior epigastric artery measured by color-coded duplex sonography. Further experience is needed before near-infrared reflection spectroscopy can be advocated for routine clinical flap monitoring.
Similar articles
-
Tissue oxygenation and perfusion in inferior pedicle reduction mammaplasty by near-infrared reflection spectroscopy and color-coded duplex sonography.Plast Reconstr Surg. 2003 Mar;111(3):1131-46. doi: 10.1097/01.PRS.0000046615.36917.3E. Plast Reconstr Surg. 2003. PMID: 12621183
-
A hemodynamic approach to clinical results in the TRAM flap after selective delay.Plast Reconstr Surg. 1997 May;99(6):1706-14. Plast Reconstr Surg. 1997. PMID: 9145142 Clinical Trial.
-
[Clinical results and color-coded duplex ultrasound findings 4 years after conditioned TRAM flap-plasty].Zentralbl Chir. 2000;125(1):60-7. Zentralbl Chir. 2000. PMID: 10703170 German.
-
Optimizing pedicled transverse rectus abdominis muscle flap breast reconstruction.Cancer J. 2008 Jul-Aug;14(4):236-40. doi: 10.1097/PPO.0b013e318180bce5. Cancer J. 2008. PMID: 18677131 Review.
-
The use of pedicled tram flap for delayed breast reconstruction.Acta Chir Plast. 2001;43(1):7-10. Acta Chir Plast. 2001. PMID: 11370257 Review.
Cited by
-
[Intra- and postoperative monitoring of transplanted flaps. Measurement of the partial pressure of oxygen in tissue].Mund Kiefer Gesichtschir. 2004 Nov;8(6):361-8. doi: 10.1007/s10006-004-0566-4. Epub 2004 Sep 18. Mund Kiefer Gesichtschir. 2004. PMID: 15378400 German.
-
Prediction of post-operative necrosis after mastectomy: a pilot study utilizing optical diffusion imaging spectroscopy.World J Surg Oncol. 2009 Nov 25;7:91. doi: 10.1186/1477-7819-7-91. World J Surg Oncol. 2009. PMID: 19939277 Free PMC article.
-
Postoperative quantitative assessment of reconstructive tissue status in a cutaneous flap model using spatial frequency domain imaging.Plast Reconstr Surg. 2011 Jan;127(1):117-130. doi: 10.1097/PRS.0b013e3181f959cc. Plast Reconstr Surg. 2011. PMID: 21200206 Free PMC article.
-
Early detection of complete vascular occlusion in a pedicle flap model using quantitative [corrected] spectral imaging.Plast Reconstr Surg. 2010 Dec;126(6):1924-1935. doi: 10.1097/PRS.0b013e3181f447ac. Plast Reconstr Surg. 2010. PMID: 21124132 Free PMC article.
-
Blood perfusion of the free anterolateral thigh perforator flap: its beneficial effect in the reconstruction of infected wounds in the lower extremity.World J Surg. 2007 Jan;31(1):11-8. doi: 10.1007/s00268-006-0298-8. World J Surg. 2007. PMID: 17171492
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical