Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Jan;79(1):24-34.
doi: 10.4065/79.1.24.

Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale

Affiliations

Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale

Michael G Earing et al. Mayo Clin Proc. 2004 Jan.

Abstract

Objectives: To describe our experience with intracardiac echocardiographic (ICE) guidance during transcatheter device closure of atrial septal defect (ASD) and patent foramen ovale (PFO) and to describe a detailed stepwise approach for performing ICE examinations.

Patients and methods: We reviewed the ICE results of all patients who underwent transcatheter device closure of ASD/PFO at the Mayo Clinic in Rochester, Minn, between October 2000 and November 2002. Conscious sedation was used, and all ICE studies were performed using a diagnostic ultrasound catheter.

Results: Ninety-four patients (47 male; median age, 51 years [range, 17-81 years]) underwent ICE during transcatheter device closure of ASD/PFO. Total procedure time was 128 minutes (range, 27-320 minutes). ICE identified a previously unrecognized anatomical diagnosis in 32 of 94 patients. An additional ASD or PFO was found in 16 patients; a redundant atrial septum or an atrial septal aneurysm was found in 12 patients. There were few ICE complications (4%): 3 patients developed atrial fibrillation, and 1 developed supraventricular tachycardia; of these 4, 2 resolved spontaneously, and 2 required cardioversion with no recurrence.

Conclusion: ICE provides anatomical detail of ASD/PFO and cardiac structures facilitating congenital cardiac interventional procedures. ICE eliminates major drawbacks related to the use of transesophageal echocardiographic guidance for transcatheter device closure of ASD/PFO, specifically problems related to airway management. Finally, ICE gives the interventional cardiologist the ability to control all aspects of imaging without relying on additional echocardiographic support. We believe that ICE should be considered the preferred imaging technique for guidance of transcatheter device closure of ASD/PFO in adults and larger pediatric patients.