Objective: To review our experience with, and profile the safety and efficacy of, the Amplatzer PFO (patent foramen ovale) occluder (APO) and Amplatzer septal occluder (ASO) used to close PFO and/or atrial septal defect (ASD) in patients with paradoxical embolism (PE).
Patients and methods: Between April 1998 and November 2002, 103 patients at the Mayo Clinic in Rochester, Minn, and Scottsdale, Ariz, mean age 52.4 years, with presumed PE (transient ischemic attack [n=22], stroke [n=77], or peripheral emboli [n=4]) underwent transcatheter device closure of PFO (n=81), ASD (n=12), and ASD/PFO (n=10) with 106 devices (APO [n=22] or ASO [n=84]).
Results: All devices deployed successfully, and no patients died. Procedural complications included atrial fibrillation (n=2), vessel injury (n=3), profound sinus node dysfunction (n=1), and device embolization with successful retrieval (n=1). At 3 months, 7 of 95 monitored patients had trivial residual shunt; at 12 months, 2 of 28 monitored patients had trivial residual shunt. Three patients had recurrent events--2 transient ischemic attacks and 1 retinal artery occlusion--at a mean +/- SD follow-up of 8.3 +/- 8.1 months (range, 1-34 months). None of these 3 patients had residual shunt or evidence of intracardiac thrombus. The average annual recurrence of all events was 3.6% at 23 months. The overall mean +/- SD freedom from recurrence of all events was 98.9% +/- 1.2% and 83.8% +/- 10.2% at 12 and 29 months of follow-up, respectively.
Conclusions: Transcatheter device closure of PFO and/or ASD with use of APO/ASO in patients with presumed PE is effective and safe. Recurrent events may occur in the absence of a residual shunt.
Comment in
-
Patent foramen ovale: paradoxical embolism and paradoxical data.Mayo Clin Proc. 2004 Jan;79(1):15-20. doi: 10.4065/79.1.15. Mayo Clin Proc. 2004. PMID: 14708944 Review. No abstract available.
Similar articles
-
Paradoxical emboli in children and young adults: role of atrial septal defect and patent foramen ovale device closure.Mayo Clin Proc. 2006 May;81(5):615-8. doi: 10.4065/81.5.615. Mayo Clin Proc. 2006. PMID: 16706258
-
Interventional closure with Amplatzer PFO occluder of patent foramen ovale in patients with paradoxical cerebral embolism.J Interv Cardiol. 2005 Jun;18(3):173-9. doi: 10.1111/j.1540-8183.2005.04050.x. J Interv Cardiol. 2005. PMID: 15966921
-
Late results after percutaneous closure of patent foramen ovale for secondary prevention of paradoxical embolism using the amplatzer PFO occluder without intraprocedural echocardiography: effect of device size.JACC Cardiovasc Interv. 2009 Feb;2(2):116-23. doi: 10.1016/j.jcin.2008.09.013. JACC Cardiovasc Interv. 2009. PMID: 19463412
-
AMPLATZER Septal Occluder failure resulting in paradoxical cerebral embolism.Tex Heart Inst J. 2012;39(5):647-52. Tex Heart Inst J. 2012. PMID: 23109759 Free PMC article. Review.
-
Transcatheter Closure of Atrial Septal Defect: A Review of Currently Used Devices.Cureus. 2023 Jun 8;15(6):e40132. doi: 10.7759/cureus.40132. eCollection 2023 Jun. Cureus. 2023. PMID: 37425612 Free PMC article. Review.
Cited by
-
Comparison of Intracardiac Echocardiography and Transesophageal Echocardiography for Image Guidance in Percutaneous Patent Foramen Ovale Closure.Medicina (Kaunas). 2020 Aug 9;56(8):401. doi: 10.3390/medicina56080401. Medicina (Kaunas). 2020. PMID: 32784843 Free PMC article.
-
Atrial septal defects - clinical manifestations, echo assessment, and intervention.Clin Med Insights Cardiol. 2015 Mar 23;8(Suppl 1):93-8. doi: 10.4137/CMC.S15715. eCollection 2014. Clin Med Insights Cardiol. 2015. PMID: 25861226 Free PMC article. Review.
-
Transcatheter closure of secundum atrial septal defects in adults with the Amplatzer septal occluder: intermediate and long-term results.Clin Res Cardiol. 2007 Jun;96(6):340-6. doi: 10.1007/s00392-007-0502-3. Epub 2007 Feb 26. Clin Res Cardiol. 2007. PMID: 17323009
-
Persistent Atrial Septum Defect Despite Placement of Two Amplatzer Septal Occluders.J Cardiovasc Thorac Res. 2015;7(4):172-4. doi: 10.15171/jcvtr.2015.37. Epub 2015 Nov 28. J Cardiovasc Thorac Res. 2015. PMID: 26702348 Free PMC article.
-
Patent foramen ovale: the never-ending story.Curr Treat Options Cardiovasc Med. 2005 Jul;7(3):227-39. doi: 10.1007/s11936-005-0051-x. Curr Treat Options Cardiovasc Med. 2005. PMID: 16004854
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous