Research into the development of a wearable bioartificial kidney with a continuous hemofilter and a bioartificial tubule device using tubular epithelial cells

Affiliations
Clinical Trial

Research into the development of a wearable bioartificial kidney with a continuous hemofilter and a bioartificial tubule device using tubular epithelial cells

Akira Saito. Artif Organs. 2004 Jan.

Abstract

Current hemodialysis treatment is insufficient because of intermittent treatment and loss of tubular function. In order to overcome the loss of tubular function, a bioartificial kidney has been developed consisting of continuous hemofiltration (CHF) with 10 L/day of filtrate and a bioartificial tubule device using proximal tubular epithelial cells and hollow fiber membranes. Ten L/day of CHF enabled plasma levels of urea, creatinine, uric acid and, beta2-microglobulin in eight renal failure patients to be maintained at remarkably low levels. The concept was tested with 6 L (4 mL/min) of 10 L/day (7 mL/min) filtrate regenerated by a bioartificial tubule device and 4 L/day (3 mL/min) replaced by food and drinks. Lewis lung cancer-porcine kidney 1 (LLC-PK1) cells with a cell density of 107 cells/mL were seeded inside polysulfone hollow fiber modules four times at 1 h intervals while rotating the module 90 degrees each time, and were cultured for 48 h to form confluent monolayers. The leak rates of urea and creatinine across LLC-PK1 cell-attached polysulfone membrane modules (membrane areas: 56 cm2 and 4000 cm2) were investigated. Via conversion from 56 m2 to 1 m2 hollow fiber modules with LLC-PK1 cells for 24 h, the transport rates of H2O, glucose and Na+ were, respectively, 40, 65 and 35% of the target transported amounts from 6 L/day of filtrate. The rates are expected to approach 100% when 4-5 g/dL of albumin is added to the basal portion of the medium since the results were obtained without the addition of albumin for colloidal osmotic pressure.