Polymer membranes in clinical sensor applications. III. Hydrogels as reactive matrix membranes in fibre optic sensors
- PMID: 1472595
- DOI: 10.1016/0142-9612(92)90149-i
Polymer membranes in clinical sensor applications. III. Hydrogels as reactive matrix membranes in fibre optic sensors
Abstract
The potential of hydrogel copolymer membranes in clinical sensors, based on fibre optics, is addressed. The particular properties of the membranes of relevance in this application are the ease of refractive index modulation and the potential of the hydrogel to act as a permselective barrier in which a colorimetric agent may be immobilized. The results presented illustrate the complexity of colorimetric and refractive index effects together with their dependence on pH and tonicity for hydrogels of a given composition range. The incorporation of an acryloyl-functionalized reagent (bromopyrogallol red) is used to illustrate the way in which a working pH sensor based on these combined properties may be designed and fabricated.
Similar articles
-
Polymer membranes in clinical sensor applications. I. An overview of membrane function.Biomaterials. 1992;13(14):971-8. doi: 10.1016/0142-9612(92)90147-g. Biomaterials. 1992. PMID: 1472593 Review.
-
Polymer membranes in clinical sensor applications. II. The design and fabrication of permselective hydrogels for electrochemical devices.Biomaterials. 1992;13(14):979-90. doi: 10.1016/0142-9612(92)90148-h. Biomaterials. 1992. PMID: 1472594 Review.
-
Continuous glucose sensing with fluorescent thin-film hydrogels. 2. Fiber optic sensor fabrication and in vitro testing.Diabetes Technol Ther. 2006 Jun;8(3):279-87. doi: 10.1089/dia.2006.8.279. Diabetes Technol Ther. 2006. PMID: 16800749
-
Single fiber-optic pH sensor based on changes in reflection accompanying polymer swelling.Anal Chem. 1994 May 15;66(10):1731-5. doi: 10.1021/ac00082a021. Anal Chem. 1994. PMID: 8030785
-
Localized biosensing with Topas microstructured polymer optical fiber.Opt Lett. 2007 Mar 1;32(5):460-2. doi: 10.1364/ol.32.000460. Opt Lett. 2007. PMID: 17392887
Cited by
-
Why is the Sensory Response of Organic Probes within a Polymer Film Different in Solution and in the Solid-State? Evidence and Application to the Detection of Amino Acids in Human Chronic Wounds.Polymers (Basel). 2020 May 29;12(6):1249. doi: 10.3390/polym12061249. Polymers (Basel). 2020. PMID: 32486091 Free PMC article.
-