Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Jan;77(1):93-101.
doi: 10.1016/s0003-4975(03)01331-6.

Patencies of 2127 arterial to coronary conduits over 15 years

Affiliations

Patencies of 2127 arterial to coronary conduits over 15 years

James Tatoulis et al. Ann Thorac Surg. 2004 Jan.

Abstract

Background: Use of arterial grafts in coronary surgery is based on the excellent patency of the left internal thoracic artery (LITA) and an expectation that other arterial grafts-right internal thoracic artery (RITA) and radial artery (RA)-will give similar patencies, superior to saphenous vein. We examined patencies of arterial grafts in a practice with extensive use for more than 15 years.

Methods: Consecutive postoperative angiograms of 2,127 arterial/coronary conduits were evaluated. Angiograms were performed for cardiac symptoms. Assessment was by two observers. String signs were considered as occlusions.

Results: There were 2127 arterial conduits. Overall patencies were as follows: LITA, 96.4% (1296 of 1345); RITA, 88.3% (534 of 605); aortocoronary RA, 89.3% (158 of 177). The LITA patency to the left anterior descending artery was 97.1% (1131 of 1165); to the obtuse marginal artery it was 91.7% (165 of 180; p 0.01). The RITA pedicled graft patency was 86% (275 of 321) compared with free RITA, 91% (259 of 284; p = not significant). For RITA there was a hierarchy of patency for coronary territory grafted (left anterior descending artery best, right coronary/posterior descending artery worst) and for degree of coronary stenosis: if stenosis was less than 60%, patency was 65% (47 of 72); if stenosis was more than 60%, patency was 90.9% (485 of 533; p = 0.0001). Similarly for the radial artery there was higher patency with greater coronary stenosis. The LITA patency at 5 years was 98%, at 10 years it was 95%, and at 15 years it was 88%. The RITA patency at 5 years was 96%, at 10 years it was 81%, and at 15 years it was 65%. The radial artery patency at 1 year was 96% and at 4 years it was 89%. For 3,714 vein grafts also studied overall patency was 61% (2266 of 3214) with patencies of 95% at 5 years, 71% at 10 years, and 32% at 15 years.

Conclusions: Excellent long-term patencies of arterial grafts are noted, superior to those of vein grafts. Patencies were influenced by conduit, by distribution, and by coronary artery stenosis.

PubMed Disclaimer