A review of suturing techniques for posterior chamber lenses
- PMID: 14743019
- DOI: 10.1097/00055735-200402000-00009
A review of suturing techniques for posterior chamber lenses
Abstract
Purpose of review: To evaluate the outcome of last the 15 years' experience with the transscleral suture fixation technique of posterior chamber intraocular lens (PC IOL).
Recent findings: The implant of an anterior chamber IOL, especially the iris-claw lens, is safer and a better option than the transsclerally fixed IOL.
Summary: After bibliographic review of anterior chamber lenses implant results with transscleral fixation, we conclude that the number of complications is less in the iris fixation lens.