Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease
- PMID: 14752472
- DOI: 10.1016/j.nuclcard.2003.09.010
Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease
Abstract
Background: Although myocardial gated single photon emission computed tomography (SPECT) is routinely used for functional measurements in patients with coronary artery disease (CAD) and heart failure, day-to-day variability of left ventricular ejection fraction (LVEF), left ventricular (LV) volumes, and global perfusion scoring has not yet been investigated.
Methods and results: In 20 consecutive patients with CAD and an LVEF lower than 40% who routinely underwent a resting tetrofosmin gated SPECT study, we performed an additional gated SPECT study at rest 1 to 5 days later under the same circumstances. LV volumes and LVEF were calculated from the gated SPECT data by commercially available software (QGS). Myocardial perfusion was scored visually by use of a 20-segment, 5-point scoring method. For global LV function and perfusion, agreement between data was investigated by use of Bland-Altman plotting. The 95% limits of agreement found by Bland-Altman analysis were -0.9% +/- 6.0% for LVEF, 3 +/- 20 mL for LV end-diastolic volume, and 4 +/- 20 mL for LV end-systolic volume.
Conclusion: In CAD patients with an LVEF lower than 40%, day-to-day variability of measurements of global myocardial function and perfusion is quite similar to interobserver and intraobserver variability. Day-to-day variability of global LV functional parameters obtained by gated cardiac SPECT is fairly small, which indicates that myocardial gated SPECT can be used in daily clinical practice to determine changes in global LV function and perfusion over time in patients with diminished LV function.
Similar articles
-
Comparison of LVEF assessed by 2D echocardiography, gated blood pool SPECT, 99mTc tetrofosmin gated SPECT, and 18F-FDG gated PET with ERNV in patients with CAD and severe LV dysfunction.Nucl Med Commun. 2014 Nov;35(11):1156-61. doi: 10.1097/MNM.0000000000000182. Nucl Med Commun. 2014. PMID: 25144559 Clinical Trial.
-
Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123)I-labeled fatty acid analog.J Nucl Med. 2001 Dec;42(12):1747-56. J Nucl Med. 2001. PMID: 11752069
-
Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: can we use the same reference database?Ann Nucl Med. 2000 Apr;14(2):75-80. doi: 10.1007/BF02988584. Ann Nucl Med. 2000. PMID: 10830523
-
Comparison of global and regional left ventricular function assessed by gated-SPECT and 2-D echocardiography.Rev Port Cardiol. 2000 Feb;19 Suppl 1:I39-46. Rev Port Cardiol. 2000. PMID: 10750438 Review.
-
Advances in quantitative perfusion SPECT imaging.J Nucl Cardiol. 2004 Jan-Feb;11(1):62-70. doi: 10.1016/j.nuclcard.2003.10.007. J Nucl Cardiol. 2004. PMID: 14752474 Review.
Cited by
-
Fractional flow reserve and myocardial viability as assessed by SPECT perfusion scintigraphy in patients with prior myocardial infarction.J Nucl Cardiol. 2010 Oct;17(5):817-24. doi: 10.1007/s12350-010-9251-1. Epub 2010 Jun 4. J Nucl Cardiol. 2010. PMID: 20524100
-
Relationship between infarct size and severity measured by gated SPECT and long-term left ventricular remodelling after acute myocardial infarction.Eur J Nucl Med Mol Imaging. 2011 Jun;38(6):1124-31. doi: 10.1007/s00259-011-1739-7. Epub 2011 Feb 15. Eur J Nucl Med Mol Imaging. 2011. PMID: 21327635
-
Incremental prognostic value of combined perfusion and function assessment during myocardial gated SPECT in patients aged 75 years or older.J Nucl Cardiol. 2005 Nov-Dec;12(6):662-70. doi: 10.1016/j.nuclcard.2005.08.002. J Nucl Cardiol. 2005. PMID: 16344228 Clinical Trial.
-
The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene.Eur J Nucl Med Mol Imaging. 2007 Jul;34(7):1107-22. doi: 10.1007/s00259-007-0405-6. Eur J Nucl Med Mol Imaging. 2007. PMID: 17384947 Review.
-
Low-dose single acquisition rest (99m)Tc/stress (201)Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation.Eur J Nucl Med Mol Imaging. 2014 Mar;41(3):536-47. doi: 10.1007/s00259-013-2551-3. Epub 2013 Sep 13. Eur J Nucl Med Mol Imaging. 2014. PMID: 24030670 Clinical Trial.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous