Class separation of buildings with high and low prevalence of SBS by principal component analysis
- PMID: 14756842
- DOI: 10.1111/j.1600-0668.2004.00203.x
Class separation of buildings with high and low prevalence of SBS by principal component analysis
Abstract
In this study, we were able to separate buildings with high and low prevalence of sick building syndrome (SBS) using principal component analysis. The prevalence of SBS was defined by the presence of at least one typical skin, mucosal and general (headache and fatigue) symptom. Data from the Swedish Office Illness Study describing the presence and level of chemical compounds in outdoor, supply, and room air, respectively, were evaluated together with information about the buildings in six models. When all data were included the most complex model was able to separate 71% of the high prevalence buildings from the low prevalence buildings. The most important variable that separates the high prevalence buildings from the low prevalence buildings was a more frequent occurrence or a higher concentration of compounds with shorter retention time in the high prevalence buildings. Elevated relative humidity in supply and room air and higher levels of total volatile organic compounds in outdoor and supply air were more common in high prevalence buildings. Ten building variables also contributed to the separation of the two classes of low and high prevalence buildings.
Similar articles
-
Association of ventilation system type with SBS symptoms in office workers.Indoor Air. 2002 Jun;12(2):98-112. doi: 10.1034/j.1600-0668.2002.01111.x. Indoor Air. 2002. PMID: 12216473 Review.
-
Outdoor air pollution, meteorological conditions and indoor factors in dwellings in relation to sick building syndrome (SBS) among adults in China.Sci Total Environ. 2016 Aug 1;560-561:186-96. doi: 10.1016/j.scitotenv.2016.04.033. Epub 2016 Apr 19. Sci Total Environ. 2016. PMID: 27101454
-
A longitudinal study of sick building syndrome (SBS) among pupils in relation to SO2, NO2, O3 and PM10 in schools in China.PLoS One. 2014 Nov 14;9(11):e112933. doi: 10.1371/journal.pone.0112933. eCollection 2014. PLoS One. 2014. PMID: 25398002 Free PMC article.
-
Building sickness syndrome in healthy and unhealthy buildings: an epidemiological and environmental assessment with cluster analysis.Occup Environ Med. 2000 Sep;57(9):627-34. doi: 10.1136/oem.57.9.627. Occup Environ Med. 2000. PMID: 10935944 Free PMC article.
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
Cited by
-
Medical and social prognoses of non-specific building-related symptoms (Sick Building Syndrome): a follow-up study of patients previously referred to hospital.Int Arch Occup Environ Health. 2008 Jul;81(7):805-12. doi: 10.1007/s00420-007-0267-z. Epub 2007 Oct 9. Int Arch Occup Environ Health. 2008. PMID: 17924130
-
Airborne environmental injuries and human health.Clin Rev Allergy Immunol. 2006 Aug;31(1):1-101. doi: 10.1385/CRIAI:31:1:1. Clin Rev Allergy Immunol. 2006. PMID: 16960302 Free PMC article. Review.
-
Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds.Int J Environ Res Public Health. 2015 May 27;12(6):5833-45. doi: 10.3390/ijerph120605833. Int J Environ Res Public Health. 2015. PMID: 26024357 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources