. 1992 Nov:98:227-34.
doi: 10.1289/ehp.9298227.

Development of source testing, analytical, and mutagenicity bioassay procedures for evaluating emissions from municipal and hospital waste combustors

Affiliations

Development of source testing, analytical, and mutagenicity bioassay procedures for evaluating emissions from municipal and hospital waste combustors

R R Watts et al. Environ Health Perspect. 1992 Nov.

Abstract

Incineration is currently being used for disposal of about 10% of the solid waste generated in the United States, and this percentage will likely increase as land disposal declines. Siting new incinerators, however, is often controversial because of concerns related to the possibility of adverse health effects and environmental contamination from long-term exposure to stack emissions. Specific concerns relate to the adequacies of a) stack emission testing protocols, b) existing regulations, and c) compliance monitoring and enforcement of regulations. U.S. Environmental Protection Agency laboratories are cooperatively conducting research aimed at developing new testing equipment and procedures that will allow a more comprehensive assessment of the complex mixture of organics that is present in stack emissions. These efforts are directed specifically toward developing source testing equipment and procedures, analytical procedures, and bioassay procedures. The objectives of this study were to field test two types of high-volume source dilution samplers, collect stack samples for use in developing analytical and mutagenicity bioassay procedures, and determine mutagenicity of organics associated with emission particles from two municipal waste combustors and a hospital waste combustor. Data are presented for particle concentrations and emission rates, extractable organic concentrations and emission rates, and Salmonella (Ames) mutagenic potency and emission rates. The mutagenic emission rates and emission factors are compared to other incinerators and combustion sources.

PubMed Disclaimer

References

    1. Mutat Res. 1991 Feb;252(1):35-44 - PubMed
    1. Fundam Appl Toxicol. 1988 May;10(4):571-89 - PubMed
    1. J Air Pollut Control Assoc. 1985 Aug;35(8):849-56 - PubMed
    1. Mutat Res. 1983 Jul;121(1):25-32 - PubMed
    1. Mutat Res. 1988 Jan;204(1):17-115 - PubMed

Publication types

LinkOut - more resources