High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience
- PMID: 14872368
- DOI: 10.1055/s-2004-817623
High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience
Erratum in
- Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2004 Apr;176(4):622
Abstract
Purpose: To combine whole-body multi-station three-dimensional contrast enhanced magnetic resonance angiography (3D CE MRA) using a self-developed rolling table platform with parallel imaging strategies (PAT) in order to increase the spatial resolution of the 3D MRA data sets.
Materials and methods: Whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol.
Results: Compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition.
Conclusion: The implementation of PAT into the concept of whole-body MRA enabled to increase the spatial resolution in all examined territories, which resulted in more detailed MR angiograms.
Similar articles
-
High-resolution magnetic resonance angiography of the lower extremities with a dedicated 36-element matrix coil at 3 Tesla.Invest Radiol. 2007 Jun;42(6):477-83. doi: 10.1097/01.rli.0000263183.66407.69. Invest Radiol. 2007. PMID: 17507821
-
Optimization of contrast-enhanced peripheral MR angiography with mid-femoral venous compression (VENCO).Rofo. 2004 Feb;176(2):157-62. doi: 10.1055/s-2004-817622. Rofo. 2004. PMID: 14872367
-
High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between 2 different acceleration factors at 3.0 Tesla.Invest Radiol. 2006 Apr;41(4):391-9. doi: 10.1097/01.rli.0000197978.88991.17. Invest Radiol. 2006. PMID: 16523022
-
Extracranial carotid MR imaging at 3T.Magn Reson Imaging Clin N Am. 2006 Feb;14(1):109-21. doi: 10.1016/j.mric.2005.12.003. Magn Reson Imaging Clin N Am. 2006. PMID: 16530639 Review.
-
[Three-dimensional contrast-enhanced MR angiography].Orv Hetil. 2003 Jul 20;144(29):1419-25. Orv Hetil. 2003. PMID: 12939862 Review. Hungarian.
Cited by
-
Parallel reconstruction using null operations.Magn Reson Med. 2011 Nov;66(5):1241-53. doi: 10.1002/mrm.22899. Epub 2011 May 20. Magn Reson Med. 2011. PMID: 21604290 Free PMC article.
-
Whole-Body MRA.Eur Radiol. 2008 Sep;18(9):1925-36. doi: 10.1007/s00330-007-0817-5. Epub 2008 May 20. Eur Radiol. 2008. PMID: 18491112 Review.
-
Clinical value of whole-body magnetic resonance imaging in health screening of general adult population.Radiol Oncol. 2015 Mar 3;49(1):10-6. doi: 10.2478/raon-2014-0031. eCollection 2015 Mar. Radiol Oncol. 2015. PMID: 25810696 Free PMC article.
-
Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography.J Magn Reson Imaging. 2014 May;39(5):1161-70. doi: 10.1002/jmri.24266. Epub 2013 Jul 29. J Magn Reson Imaging. 2014. PMID: 23897776 Free PMC article.
-
[Prognostic value of cardiovascular MRI in diabetics].Radiologe. 2015 Apr;55(4):299-307. doi: 10.1007/s00117-014-2719-2. Radiologe. 2015. PMID: 25711144 German.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources