Electric and dielectric properties of wet human cortical bone as a function of frequency
- PMID: 1487293
- DOI: 10.1109/10.184706
Electric and dielectric properties of wet human cortical bone as a function of frequency
Abstract
In this paper, the electrical and dielectric properties of wet human cortical bone from a distal tibia were examined as a function of frequency and direction. The resistance and capacitance of the cortical bone specimens were measured at near 100% relative humidity. The measurements were made in all three orthogonal directions at discrete frequencies ranging from 120 Hz to 10 MHz using an LCR meter. At a frequency of 100 kHz, the mean resistivity and specific capacitance for the ten cortical bone specimens were 1.55 k omega-cm and 33.81 pF/cm in the axial direction, 15.79 k omega-cm and 9.98 pF/cm in the circumferential direction, and 21.5 k omega-cm and 9.83 pF/cm in the radial direction. All electrical and dielectric properties except the resistivity and the specific impedance were highly frequency dependent for the frequency range tested. However, the resistivity and specific impedance were relatively less frequency dependent. All electrical and dielectric properties were also transversely isotropic in nature, the values for the axial direction being different from the values obtained for the two transverse directions.
Similar articles
-
The electrical and dielectric properties of human bone tissue and their relationship with density and bone mineral content.Ann Biomed Eng. 1996 Mar-Apr;24(2):222-33. doi: 10.1007/BF02667351. Ann Biomed Eng. 1996. PMID: 8678354
-
Electric and dielectric properties of wet human cancellous bone as a function of frequency.Ann Biomed Eng. 1989;17(2):143-58. doi: 10.1007/BF02368024. Ann Biomed Eng. 1989. PMID: 2729682
-
Comparison of the electrical and dielectric behavior of wet human cortical and cancellous bone tissue from the distal tibia.J Orthop Res. 1995 Jul;13(4):524-32. doi: 10.1002/jor.1100130407. J Orthop Res. 1995. PMID: 7674068
-
Electrical properties of bone. A review.Clin Orthop Relat Res. 1984 Jun;(186):249-71. Clin Orthop Relat Res. 1984. PMID: 6373088 Review.
-
Mechanisms responsible for electrical properties of tissues and cell suspensions.Med Prog Technol. 1993-1994;19(4):163-5. Med Prog Technol. 1993. PMID: 8052170 Review.
Cited by
-
Dielectric properties of bones for the monitoring of osteoporosis.Med Biol Eng Comput. 2019 Jan;57(1):1-13. doi: 10.1007/s11517-018-1887-z. Epub 2018 Aug 29. Med Biol Eng Comput. 2019. PMID: 30159660 Review.
-
The electrical and dielectric properties of human bone tissue and their relationship with density and bone mineral content.Ann Biomed Eng. 1996 Mar-Apr;24(2):222-33. doi: 10.1007/BF02667351. Ann Biomed Eng. 1996. PMID: 8678354
-
Effects of tissue resistivities on electroencephalogram sensitivity distribution.Med Biol Eng Comput. 1999 Sep;37(5):555-9. doi: 10.1007/BF02513348. Med Biol Eng Comput. 1999. PMID: 10723891
-
Gathering Evidence to Leverage Musculoskeletal Magnetic Stimulation Towards Clinical Applicability.Small Sci. 2024 Feb 26;4(5):2300303. doi: 10.1002/smsc.202300303. eCollection 2024 May. Small Sci. 2024. PMID: 40213569 Free PMC article.
-
A finite element model of electrode placement during stimulus evoked electromyographic monitoring of iliosacral screw insertion.Open Orthop J. 2008 Mar 10;2:33-9. doi: 10.2174/1874325000802010033. Open Orthop J. 2008. PMID: 19587797 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources