Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Jul;14(7):1234-40.
doi: 10.1007/s00330-004-2250-3. Epub 2004 Feb 13.

Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions

Affiliations

Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions

Michel Montaudon et al. Eur Radiol. 2004 Jul.

Abstract

The purpose of this study was to evaluate the performance and complication rate of CT-guided percutaneous lung biopsy of pulmonary lesions using a coaxial automated biopsy device and to determine factors influencing the false negative rate for the diagnosis of malignancy. A prospective study of 605 consecutive biopsies performed in 595 patients was undertaken. The performances for the diagnosis of malignancy, for the specific diagnosis of benignity and the complication rate were calculated. Patients' characteristics and lesion and procedure variables were included in a logistic regression model and analyzed as potential predictive variables for occurrence of a false-negative diagnosis of malignancy. The sensitivity, specificity, positive predictive value and negative predictive value for a diagnosis of malignancy were 92.2, 99.1, 99.8 and 73.3%, respectively. A specific diagnosis of benignity was obtained in 43 cases (40%) biopsies. The pneumothorax rate was 17.4% (n = 105) with 3 (0.5%) requiring drainage. At multivariate analysis, the sole variable significantly associated with a higher rate of false negative diagnosis of malignancy was lesion size equal to or smaller than 10 mm in diameter. Using a coaxial automated device, CT-guided percutaneous biopsy of pulmonary lesions of size equal to or less than 10 mm in diameter provides a high diagnostic yield with an acceptable complication rate.

PubMed Disclaimer

References

    1. Clin Radiol. 1996 Jul;51(7):503-6 - PubMed
    1. AJR Am J Roentgenol. 2003 Mar;180(3):811-5 - PubMed
    1. AJR Am J Roentgenol. 1997 Sep;169(3):661-6 - PubMed
    1. Acta Cytol. 1995 May-Jun;39(3):463-71 - PubMed
    1. Mayo Clin Proc. 1980 Aug;55(8):475-81 - PubMed