Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Feb 15;93(4):437-40.
doi: 10.1016/j.amjcard.2003.10.037.

Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect

Affiliations
Comparative Study

Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect

Fernando Boccalandro et al. Am J Cardiol. .

Abstract

Transcatheter closure of interatrial septal defects is guided by transesophageal echocardiography (TEE), which requires general anesthesia in most cases. Using a new intracardiac echocardiographic (ICE) catheter may avoid endotracheal and esophageal intubation while using only local anesthesia. Forty-two patients underwent transcatheter interatrial septal defect closure; half of them underwent TEE guidance with general anesthesia and the other half underwent ICE guidance with local anesthesia. Device deployment success rate, adequate 2-dimensional and Doppler visualization of the defect and deployment steps, interatrial communication closure at 24 hours, and at 3 and 6 months, procedure time length, complications, fluoroscopic time, and length of hospitalization were compared between both methods. All interventions were completed successfully with no complications, except for 1 patient in the TEE group who had a minor oral trauma. Echocardiographic visualization of the septal defect and deployment was adequate by both methods. Catheterization laboratory time (92 +/- 18 vs 50 +/- 12 minutes, p <0.001) and interventional procedure length (47 +/- 8 vs 35 +/- 6 minutes, p <0.001) were shortened using ICE. There was no difference in the rate of closure after 6-month follow-up by either method. ICE guidance offers equivalent echocardiographic views compared with TEE and similar rates of closure. ICE is associated with decreased procedure length while eliminating the risks of endotracheal or esophageal intubation and general anesthesia.

PubMed Disclaimer

Publication types

LinkOut - more resources