Verification of the pressure provocative test in carpal tunnel syndrome
- PMID: 1497301
- DOI: 10.1097/00000637-199207000-00003
Verification of the pressure provocative test in carpal tunnel syndrome
Abstract
Three provocative tests (pressure, Phalen's test, and Tinel's sign) were studied in 30 patients with carpal tunnel syndrome and 30 control subjects. The pressure provocative test had a sensitivity of 100%. In contrast, Phalen's test was 88% sensitive and Tinel's sign only 67% sensitive. The pressure provocative test is a sensitive indicator of median nerve compression at the wrist with a faster reaction time than Phalen's test (mean time of 9 seconds vs 30 seconds). It is an appropriate provocative test in patients with stiff or painful wrists when wrist flexion is restricted.