Shear bond strengths and microleakage of four types of dentin adhesive materials
- PMID: 14973561
Shear bond strengths and microleakage of four types of dentin adhesive materials
Abstract
The aim of this investigation was to compare the microleakage of composite resin (Z-100) and shear bond strength to bovine dentin using different types of adhesive systems (Scotch Bond Multi-Purpose, All-Bond 2, One-Step, and Perma Quick) to compare and correlate microleakage to shear bond strength. For the microleakage aspect of the study, 20 class V were prepared (bovine incisors) with 90-degree cavosurface margins and were located at the cemento-enamel junction using a template. Each dentin bonding system was applied to five cavities following the manufacturer's instructions and restored with Z-100 composite resin. After 24 hours of storage in distilled water at 37 degrees C, the teeth were immersed in 2% basic fuchsin dye. All teeth were sectioned in a mesiodistal direction using a diamond saw, and each section was then inspected under a stereomacroscope. For the shear bond strength aspect of the study, 20 bovine incisors were centrally horizontally mounted in Teflon mold with cold cure acrylic resin. Flat labial dentin surfaces were prepared using different grit silicon carbide abrasive wheels. Five specimens were used for each of the bonding agent systems. Each specimen was bonded with restorative composite resin (Z-100) and applied to the treated dentinal surface through a split Teflon mold. All specimens were stored in distilled water at 37 degrees C for 24 hours. The bonds were stressed using shear forces at a crosshead speed of 0.5mm/min using an Instron Universal testing machine. Findings indicate none of the systems tested in this study were free from microleakage. Scotch bond multi-purpose achieved the best seal, with One-Step being second best, while All-Bond 2 and Perma Quick had the poorest seal. However, there were significant differences among the shear bond strengths of the four bonding systems tested. Scotch Bond Multi-Purpose has a higher bond strength to composite resin when compared to the other dentin adhesives. The study also concluded there is no association between microleakage and shear bond strength.
Similar articles
-
Microleakage of light-cured resin and resin-modified glass-ionomer dentin bonding agents applied with co-cure vs pre-cure technique.Oper Dent. 2000 Jul-Aug;25(4):292-8. Oper Dent. 2000. PMID: 11203833 Clinical Trial.
-
Shear bond strengths of two composite core materials after using all-in-one and single-bottle dentin adhesives.J Prosthodont. 2005 Jun;14(2):97-103. doi: 10.1111/j.1532-849X.2005.00018.x. J Prosthodont. 2005. PMID: 16011620
-
An in vitro shear bond strength study of enamel/dentin bonding systems on enamel.Oper Dent. 1995 Sep-Oct;20(5):174-9. Oper Dent. 1995. PMID: 8710695
-
Current status of dentin adhesive systems.Alpha Omegan. 1998 Dec;91(4):17-22. Alpha Omegan. 1998. PMID: 10634094 Review.
-
Relevance of in vitro tests of adhesive and composite dental materials. A review in 3 parts. Part 3: in vitro tests of adhesive systems.Schweiz Monatsschr Zahnmed. 2011;121(11):1024-40. Schweiz Monatsschr Zahnmed. 2011. PMID: 22139713 Review. English, German.
Cited by
-
The effects of dentin bonding agent formulas on their polymerization quality, and together with tooth tissues on their microleakage and shear bond strength: an explorative 3-step experiment.J Adv Prosthodont. 2014 Oct;6(5):333-45. doi: 10.4047/jap.2014.6.5.333. Epub 2014 Oct 21. J Adv Prosthodont. 2014. PMID: 25352955 Free PMC article.
-
Shear Bond Strength of an Etch-and-rinse Adhesive to Er:YAG Laser- and/or Phosphoric Acid-treated Dentin.J Dent Res Dent Clin Dent Prospects. 2013;7(2):67-73. doi: 10.5681/joddd.2013.012. Epub 2013 May 30. J Dent Res Dent Clin Dent Prospects. 2013. PMID: 23875083 Free PMC article.
-
Microleakage in class V gingiva-shaded composite resin restorations.Ann Stomatol (Roma). 2012 Jan;3(1):19-23. Epub 2012 May 3. Ann Stomatol (Roma). 2012. PMID: 22783451 Free PMC article.
-
A comparative evaluation of the bonding efficacy of two-step vs all-in-one bonding agents - An in-vitro study.J Conserv Dent. 2009 Jul;12(3):101-4. doi: 10.4103/0972-0707.57632. J Conserv Dent. 2009. PMID: 20543915 Free PMC article.
-
To compare the microleakage among experimental adhesives containing nanoclay fillers after the storages of 24 hours and 6 months.Open Dent J. 2011 Mar 29;5:52-7. doi: 10.2174/1874210601105010052. Open Dent J. 2011. PMID: 21566692 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous