Comparison of three procedures for initial fitting of compression hearing aids. II. Experienced users, fitted unilaterally
- PMID: 14974623
- DOI: 10.1080/14992020400050003
Comparison of three procedures for initial fitting of compression hearing aids. II. Experienced users, fitted unilaterally
Abstract
This paper is the second in a series comparing three procedures for the initial fitting of multichannel compression hearing aids. The first paper reported the results for a group of 10 experienced hearing aid users fitted bilaterally. This paper reports the results for a different group of 10 experienced hearing aid users fitted unilaterally. The three procedures were: (1) CAMEQ, which aims to amplify speech so as to give equal loudness per critical band over the frequency range 500-5000 Hz, and to give similar overall loudness to normal over a wide range of speech levels; (2) CAMREST, which aims to amplify speech so as to restore normal specific loudness patterns, over a wide range of speech levels; and (3) DSL [i/o], which aims to map the dynamic range of normal-hearing people into the reduced dynamic range of hearing-impaired people, with full restoration of audibility. Each subject was fitted with one Danalogic 163D digital hearing aid, using each of the three fitting procedures in turn; the order was counter-balanced across subjects. Prescribed insertion gains for 55 and 80 dB SPL input levels were verified using real-ear measurements. Immediately after fitting with a given procedure, and 1 week after fitting. the gains were adjusted, when required, by the minimum amount necessary to achieve acceptable fittings. On average, the adjustments were smallest for the CAMREST procedure, slightly larger for the CAMEQ procedure, and largest of all for DSL [i/o]. For the DSL [i/o] the gain changes were mostly negative, especially for high frequencies and the higher input level. After these gain adjustments, users wore the aids for at least 3 weeks before speech reception thresholds (SRTs) for sentences in quiet and in steady and fluctuating background noise were measured. The APHAB questionnaire was also administered. The hearing aids were then refitted with the next procedure. SRTs and APHAB scores did not differ significantly between the three procedures. We conclude that the CAMEQ and CAMREST procedures provide a more appropriate initial fitting than DSL [i/o] for unilaterally experienced hearing aid wearers. Comparison with our earlier study based on bilateral fittings suggests that the preferred gains are similar for unilateral and bilateral fittings.
Similar articles
-
Comparison of three procedures for initial fitting of compression hearing aids. I. Experienced users, fitted bilaterally.Br J Audiol. 2001 Dec;35(6):339-53. doi: 10.1080/00305364.2001.11745252. Br J Audiol. 2001. PMID: 11848176
-
Comparison of three procedures for initial fitting of compression hearing aids. III. Inexperienced versus experienced users.Int J Audiol. 2004 Apr;43(4):198-210. doi: 10.1080/14992020400050028. Int J Audiol. 2004. PMID: 15250124
-
Is normal or less than normal overall loudness preferred by first-time hearing aid users?Ear Hear. 2004 Apr;25(2):159-72. doi: 10.1097/01.aud.0000120364.13671.e2. Ear Hear. 2004. PMID: 15064661 Clinical Trial.
-
Comparing NAL-NL1 and DSL v5 in Hearing Aids Fit to Children with Severe or Profound Hearing Loss: Goodness of Fit-to-Targets, Impacts on Predicted Loudness and Speech Intelligibility.J Am Acad Audiol. 2015 Mar;26(3):260-74. doi: 10.3766/jaaa.26.3.6. J Am Acad Audiol. 2015. PMID: 25751694
-
NAL-NL2 empirical adjustments.Trends Amplif. 2012 Dec;16(4):211-23. doi: 10.1177/1084713812468511. Epub 2012 Nov 30. Trends Amplif. 2012. PMID: 23203416 Free PMC article. Review.
Cited by
-
Hearing aid fitting and developmental outcomes of children fit according to either the NAL or DSL prescription: fit-to-target, audibility, speech and language abilities.Int J Audiol. 2018 May;57(sup2):S41-S54. doi: 10.1080/14992027.2017.1380851. Epub 2017 Oct 3. Int J Audiol. 2018. PMID: 28971727 Free PMC article. Clinical Trial.
-
Comparative studies on hearing aid selection and fitting procedures: a review of the literature.Eur Arch Otorhinolaryngol. 2008 Jan;265(1):21-9. doi: 10.1007/s00405-007-0494-7. Epub 2007 Oct 23. Eur Arch Otorhinolaryngol. 2008. PMID: 17955254 Review.
-
The Desired Sensation Level multistage input/output algorithm.Trends Amplif. 2005;9(4):159-97. doi: 10.1177/108471380500900403. Trends Amplif. 2005. PMID: 16424945 Free PMC article. Review.
-