. 2004 Mar;89(2):F168-73.
doi: 10.1136/adc.2002.023796.

Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference

Affiliations

Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference

D A Osborn et al. Arch Dis Child Fetal Neonatal Ed. 2004 Mar.

Abstract

Objective: To determine the accuracy of blood pressure (BP), capillary refill time (CRT), and central-peripheral temperature difference (CPTd) for detecting low upper body blood flow in the first day after birth.

Methods: A prospective, two centre cohort study of 128 infants born at < 30 weeks gestation. Invasive BP (n = 108), CRT (n = 128), and CPTd (n = 46) were performed immediately before echocardiographic measurement of superior vena cava (SVC) flow at three, 5-10, and 24 hours after birth.

Results: Forty four (34%) infants had low SVC flow (< 41 ml/kg/min) in the first day, 13/122 (11%) at three hours, 39/126 (31%) at 5-10 hours, and 4/119 (3%) at 24 hours. CPTd did not detect infants with low flows. Combining all observations in the first 24 hours, CRT > or = 3 seconds had 55% sensitivity and 81% specificity, mean BP < 30 mm Hg had 59% sensitivity and 77% specificity, and systolic BP < 40 mm Hg had 76% sensitivity and 68% specificity for detecting low SVC flow. Combining a mean BP < 30 mm Hg and/or central CRT > or = 3 seconds increases the sensitivity to 78%.

Conclusions: Low upper body blood flow is common in the first day after birth and strongly associated with peri/intraventricular haemorrhage. BP and CRT are imperfect bedside tests for detecting low blood flow in the first day after birth.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Scatter plot of central-peripheral temperature difference (CPTd) against superior vena cava (SVC) flow for all observations. Reference lines represent SVC flow of 41 ml/kg/min and zero CPTd.
Figure 2
Figure 2
Scatter plot of capillary refill time against superior vena cava (SVC) flow for all observations. Reference lines represent SVC flow of 41 ml/kg/min and capillary refill time of three seconds.
Figure 3
Figure 3
Scatter plot of mean blood pressure (BP) against superior vena cava (SVC) flow for all observations. Reference lines represent SVC flow of 41 ml/kg/min and mean BP of 30 mm Hg.
Figure 4
Figure 4
Scatter plot of systolic blood pressure (BP) against superior vena cava (SVC) flow for all observations. Reference lines represent SVC flow of 41 ml/kg/min and systolic BP of 40 mm Hg.

Similar articles

Cited by

References

    1. Arch Dis Child Fetal Neonatal Ed. 1996 Mar;74(2):F88-94 - PubMed
    1. J Pediatr. 1995 Nov;127(5):774-9 - PubMed
    1. J Pediatr. 1996 Oct;129(4):506-12 - PubMed
    1. Arch Dis Child Fetal Neonatal Ed. 1996 Nov;75(3):F183-6 - PubMed
    1. Arch Dis Child Fetal Neonatal Ed. 1997 Jan;76(1):F43-6 - PubMed

Publication types