A comparison of a forced-air warming system to traditional thermal support for rodent microenvironments
- PMID: 14979989
- DOI: 10.1258/00236770460734407
A comparison of a forced-air warming system to traditional thermal support for rodent microenvironments
Abstract
Thermal homeostasis is important for the well-being of laboratory rodents during experimental investigations involving chemical restraint. Anaesthesia-induced hypothermia may alter physiological processes, prolong recovery times, or result in death. Therefore, active warming may be needed to prevent excess heat loss from the rodent to the environment. Three methods of active warming were evaluated in typical rodent procedural areas and recovery cages: a forced-air warming system, infra-red heat emitter and circulating-water blanket. The first experiment involved recording the temperature of the immediate environment of the three devices, with and/or without the accompanying plastic drape, to simulate a surgical situation. In the second experiment, temperatures were recorded within cages that simulated a recovery situation with the same modalities. Forced-air warmer blankets (FAWB) were either wrapped around or placed underneath standard polycarbonate rodent cages and the results were compared with cage temperatures warmed by the heat emitter and circulating-water blanket. Temperatures were recorded at 0, 20, 40, and 60 min for each warming treatment, to determine mean temperature (+/- SEM) and the magnitude of increase (+/- SEM) between 0 and 60 min. All three devices showed an increase in temperature, but the FAWB with a plastic drape heated the procedural area microenvironment (Experiment 1) quickly and to a final temperature of 38.6 degrees C (101.5 degrees F) at 60 min, compared with 25 degrees C (77 degrees F) for the heat emitter and 28 degrees C (82.4 degrees F) for the circulating-water blanket. The magnitude of increase was significantly different for each treatment, but the FAWB with a plastic drape climbed 16.3 degrees C (29.3 degrees F) in 60 min. In Experiment 2, the FAWB wrapped around a cage, covered with a plastic drape, heated recovery cages to 32.5 degrees C (90.5 degrees F) compared to the heat emitter 26.4 degrees C (79.5 degrees F) and circulating-water blanket with drape 26.3 degrees C (79.3 degrees F). The magnitude of increase in the microenvironmental temperature was significantly higher for the FAWB, with the plastic drape wrapped around the recovery cage, compared to the other treatments. In both experiments, forced-air warming proved superior to the more traditional thermal support treatments in heating the microenvironments quickly and to an optimum ambient temperature. Forced-air warming devices should be considered when thermal support is required for rodent procedural areas and recovery cages.
Similar articles
-
Skin-surface warming: heat flux and central temperature.Anesthesiology. 1990 Aug;73(2):218-24. Anesthesiology. 1990. PMID: 2382847
-
Resistive polymer versus forced-air warming: comparable heat transfer and core rewarming rates in volunteers.Anesth Analg. 2008 Nov;107(5):1621-6. doi: 10.1213/ane.0b013e3181845502. Anesth Analg. 2008. PMID: 18931221
-
The efficacy of a resistive heating under-patient blanket versus a forced-air warming system: a randomized controlled trial.Anesth Analg. 2009 Jan;108(1):199-201. doi: 10.1213/ane.0b013e31818e6199. Anesth Analg. 2009. PMID: 19095850 Clinical Trial.
-
Forced-air warming: technology, physical background and practical aspects.Curr Opin Anaesthesiol. 2009 Dec;22(6):769-74. doi: 10.1097/ACO.0b013e328331d134. Curr Opin Anaesthesiol. 2009. PMID: 19734783 Review.
-
Prevention of perioperative hypothermia with forced-air warming systems and upper-body blankets.Surg Technol Int. 2006;15:19-22. Surg Technol Int. 2006. PMID: 17029156 Review.
Cited by
-
An MRI-Compatible High Frequency AC Resistive Heating System for Homeothermic Maintenance in Small Animals.PLoS One. 2016 Nov 2;11(11):e0164920. doi: 10.1371/journal.pone.0164920. eCollection 2016. PLoS One. 2016. PMID: 27806062 Free PMC article.
-
Use of Air-activated Thermal Devices during Recovery after Surgery in Mice.J Am Assoc Lab Anim Sci. 2018 Jul 1;57(4):392-400. doi: 10.30802/AALAS-JAALAS-17-000077. Epub 2018 Jun 22. J Am Assoc Lab Anim Sci. 2018. PMID: 29933764 Free PMC article.
-
Use of a Far-Infrared Active Warming Device in Guinea Pigs (Cavia porcellus).J Am Assoc Lab Anim Sci. 2015 Nov;54(6):779-82. J Am Assoc Lab Anim Sci. 2015. PMID: 26632788 Free PMC article.
-
Mouse Anesthesia: The Art and Science.ILAR J. 2021 Dec 31;62(1-2):238-273. doi: 10.1093/ilar/ilab016. ILAR J. 2021. PMID: 34180990 Free PMC article. Review.
-
Development of murine bariatric surgery models: lessons learned.J Surg Res. 2018 Sep;229:302-310. doi: 10.1016/j.jss.2018.04.022. Epub 2018 May 10. J Surg Res. 2018. PMID: 29937006 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources