Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Feb;21(2):129-35.
doi: 10.1046/j.1464-5491.2003.01070.x.

Facilitating access to glucometer reagents increases blood glucose self-monitoring frequency and improves glycaemic control: a prospective study in insulin-treated diabetic patients

Affiliations
Clinical Trial

Facilitating access to glucometer reagents increases blood glucose self-monitoring frequency and improves glycaemic control: a prospective study in insulin-treated diabetic patients

B L G Nyomba et al. Diabet Med. 2004 Feb.

Abstract

Aims: To investigate whether availability of glucometer reagents increases the frequency of self-blood glucose monitoring (SBGM) and improves glycaemic control in diabetic patients.

Methods: Sixty-two insulin-treated diabetic patients were randomized to two groups, matched for age, gender, education, income, type and duration of diabetes, years of insulin treatment, number of daily insulin injections, and haemoglobin (Hb)A1c. All patients were given a glucometer, but one group (no cost, NC) was provided glucometer test strips free of charge. The other group (control, C) had to purchase strips as they found it necessary. Both groups of patients were followed longitudinally at 2-monthly intervals for 12 months with measurement of blood glucose and HbA1c, and the frequency of SBGM was determined by downloading the glucometer memory.

Results: The SBGM frequency was significantly higher in the NC group vs. the C group during the first 4 months (2.0 +/- 0.2 tests/day vs. 1.4 +/- 0.1 tests/day, P<0.025). Mean HbA1c remained stable over the 12 months in the NC group, whereas an increase with time was observed in the C group. The difference in HbA1c between the two groups was significant (P<0.002) after 6 months. Random blood glucose measured at each visit and average glucose recorded by the glucometer were also lower in the NC group vs. the C group (P<0.005). There was a negative correlation between HbA1c and SBGM frequency, and HbA1c in patients testing at least twice a day was lower than in those testing less than twice a day (8.8 +/- 0.2% vs. 9.6 +/- 0.2%, P<0.001).

Conclusions: In this prospective study, having easy access to glucometer strips provided free of charge to patients increased SBGM frequency. The relationship between HbA1c and SBGM frequency supports the view that SBGM is an essential tool in diabetes management.

PubMed Disclaimer

Publication types

LinkOut - more resources