Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;19(3):283-90.
doi: 10.1002/jmri.20003.

Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging

Affiliations

Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging

Usaf E Aladl et al. J Magn Reson Imaging. 2004 Mar.

Abstract

Purpose: To develop an automatic registration method for electrocardiogram-gated myocardial perfusion single-photon emission computed tomography (SPECT) and cardiac cine-magnetic resonance imaging (MRI).

Materials and methods: Paired myocardial perfusion SPECT (MPS) and MRI from 20 patients were considered. MR images were presegmented by heart localization based on detection of cardiac motion and optimal thresholding. A registration algorithm based on mutual information was subsequently applied to all time frames or a selected subset from both modalities.

Results: A preprocessing step significantly improved the accuracy of the registration when compared to automatic registration performed without preprocessing. Errors in translation parameters (T(x), T(y), T(z)) averaged (1.0 +/- 1.5, 1.1 +/- 1.3, 0.9 +/- 0.9) pixels with MRI segmentation and (4.6 +/- 3.2, 3.4 +/- 2.6, 3.0 +/- 3.4) pixels without MRI segmentation. Errors in rotation parameters (R(x), R(y), R(z)) averaged (5.4 +/- 2.9, 3.4 +/- 2.7, 4.5 +/- 3.6) degrees with MRI segmentation and (9.3 +/- 6.1, 4.8 +/- 4.3, 14.6 +/- 12.6) degrees without MRI segmentation. Error was calculated as the absolute difference between the expert manual and the automatic registration transformation.

Conclusion: Automatic registration of gated MPS and cine MRI is possible with the use of a mutual information-based technique when MR images are presegmented. Cardiac motion can be used to isolate the left ventricle (LV) on the MR images automatically, and subsequently the segmented MR images can be coregistered with gated MPS.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources