Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;6(3):201-8.
doi: 10.1039/b311911d. Epub 2004 Jan 23.

Concentrations of polychlorinated dibenzo-p-dioxins, dibenzofurans, non-ortho polychlorinated biphenyls, and mono-ortho polychlorinated biphenyls in Japanese flounder, with reference to the relationship between body length and concentration

Affiliations

Concentrations of polychlorinated dibenzo-p-dioxins, dibenzofurans, non-ortho polychlorinated biphenyls, and mono-ortho polychlorinated biphenyls in Japanese flounder, with reference to the relationship between body length and concentration

Yutaka Okumura et al. J Environ Monit. 2004 Mar.

Abstract

The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), non-ortho polychlorinated biphenyls (non-ortho PCBs), and mono-ortho polychlorinated biphenyls (mono-ortho PCBs) in Japanese flounder (Paralichthys olivaceus, body length 10.4-36.6 cm) collected from Sendai Bay, Japan, were determined using high-resolution gas chromatography-mass spectrometry. The relationship between the concentrations of these compounds (dioxins) and the body length of the Japanese flounder was examined. The total PCDD and total PCDF concentrations did not correlate with body length (both r(2) < 0.1, both p > 0.05), whereas the total non-ortho PCB and total mono-ortho PCB (coplanar polychlorinated biphenyls, Co-PCBs) concentrations were significantly correlated (r(2)= 0.8, p < 0.05 and r(2)= 0.63, p < 0.05, respectively). The bioaccumulation properties of PCDD/Fs in Japanese flounder differed from those of Co-PCBs. Toxicity equivalency quotient (TEQ) values derived from the Co-PCBs made up 46.3%-63.7% of the total TEQ value for all the dioxins. Although the concentrations of non-ortho PCBs were lower than those of mono-ortho PCBs, the TEQ value for non-ortho PCBs was higher than that for mono-ortho PCBs. The TEQ value for non-ortho PCBs increased more with increasing body length than did the values for PCDDs, PCDFs, and mono-ortho PCBs. These results show that from the standpoint of risk management, non-ortho Co-PCBs are the most important of the dioxins in Japanese flounder.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources