Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;127(3):674-85.
doi: 10.1016/j.jtcvs.2003.11.019.

Tricuspid valve repair: durability and risk factors for failure

Affiliations
Free article

Tricuspid valve repair: durability and risk factors for failure

Patrick M McCarthy et al. J Thorac Cardiovasc Surg. 2004 Mar.
Free article

Abstract

Objectives: To compare durability of tricuspid valve annuloplasty techniques, identify risk factors for repair failure, and characterize survival, reoperation, and functional class of surviving patients.

Methods: From 1990 to 1999, 790 patients (mean age 65 +/- 12 years, 51% New York Heart Association functional class III or IV, and mean right ventricular systolic pressure 56 +/- 18 mm Hg) underwent tricuspid valve annuloplasty for functional regurgitation using 4 techniques: Carpentier-Edwards semi-rigid ring, Cosgrove-Edwards flexible band, De Vega procedure, and customized semicircular Peri-Guard annuloplasty. Of these patients, 89% had concomitant mitral valve surgery. A total of 2245 follow-up transthoracic echocardiograms were retrieved. Tricuspid regurgitation was analyzed, and risk factors for worsening regurgitation were identified, by multivariable ordinal longitudinal methods.

Results: Tricuspid regurgitation 1 week after annuloplasty was 3+ or 4+ in 14% of patients. Regurgitation severity was stable across time with the Carpentier-Edwards ring (P =.7), increased slowly with the Cosgrove-Edwards band (P =.05), and rose more rapidly with the De Vega (P =.002) and Peri-Guard (P =.0009) procedures. Risk factors for worsening regurgitation included higher preoperative regurgitation grade, poor left ventricular function, permanent pacemaker, and repair type other than ring annuloplasty. Right ventricular systolic pressure, ring size, preoperative New York Heart Association functional class, and concomitant surgery were not risk factors. Tricuspid reoperation was rare (3% at 8 years), and hospital mortality after reoperation was 37%.

Conclusions: Tricuspid valve annuloplasty did not consistently eliminate functional regurgitation, and across time regurgitation increased importantly after Peri-Guard and De Vega annuloplasties. Therefore, these repair techniques should be abandoned, and transtricuspid pacing leads should be replaced with epicardial leads.

PubMed Disclaimer

Publication types