Detection of secretion from pancreatic islets using chemically modified electrodes
- PMID: 15003559
- DOI: 10.1016/j.ab.2003.12.013
Detection of secretion from pancreatic islets using chemically modified electrodes
Abstract
Secretion of insulin from pancreatic islets was monitored indirectly by detecting zinc. Anodic stripping voltammetric measurements of zinc were done on a bismuth-modified electrode. Comparison of the performance of bismuth-modified electrodes and mercury film electrodes showed that bismuth is an appropriate alternative for Zn detection. The bismuth-coated electrode was used to detect zinc in insulin samples and insulin secreted from pancreatic islets upon stimulation with high concentrations of K(+). Detection of zinc released from pancreatic islets was done in the culture medium without any further cleanup. This detection method can be used to monitor secretion from pancreatic islets in their native environment.
Similar articles
-
Development and characterization of simulant pancreatic islets.Anal Biochem. 2003 Mar 1;314(1):38-45. doi: 10.1016/s0003-2697(02)00626-7. Anal Biochem. 2003. PMID: 12633600
-
Economic bismuth-film microsensor for anodic stripping analysis of trace heavy metals using differential pulse voltammetry.Anal Bioanal Chem. 2005 Nov;383(5):839-47. doi: 10.1007/s00216-005-0083-9. Epub 2005 Nov 5. Anal Bioanal Chem. 2005. PMID: 16215756
-
Amperometric monitoring of chemical secretions from individual pancreatic beta-cells.Anal Chem. 1993 Jul 15;65(14):1882-7. doi: 10.1021/ac00062a012. Anal Chem. 1993. PMID: 8368536
-
Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodes.Talanta. 2005 Feb 28;65(4):1052-5. doi: 10.1016/j.talanta.2004.08.060. Epub 2004 Nov 2. Talanta. 2005. PMID: 18969909
-
Comparison of the cationic and secretory response of pancreatic islets to gliclazide and/or potassium.Res Commun Chem Pathol Pharmacol. 1983 Dec;42(3):389-400. Res Commun Chem Pathol Pharmacol. 1983. PMID: 6320319
Cited by
-
A multiwalled carbon nanotube/dihydropyran composite film electrode for insulin detection in a microphysiometer chamber.Anal Chim Acta. 2008 Feb 18;609(1):44-52. doi: 10.1016/j.aca.2007.12.032. Epub 2008 Jan 6. Anal Chim Acta. 2008. PMID: 18243872 Free PMC article.
-
Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE).Anal Bioanal Chem. 2008 Jun;391(4):1283-92. doi: 10.1007/s00216-008-1948-5. Epub 2008 Mar 20. Anal Bioanal Chem. 2008. PMID: 18351328 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical