Early diagnosis of human immunodeficiency virus infection in children less than 6 months of age: comparison of polymerase chain reaction, culture, and plasma antigen capture techniques
- PMID: 1500744
- DOI: 10.1093/infdis/166.3.616
Early diagnosis of human immunodeficiency virus infection in children less than 6 months of age: comparison of polymerase chain reaction, culture, and plasma antigen capture techniques
Abstract
Three techniques were evaluated for their ability to detect human immunodeficiency virus (HIV) in infants from birth to 6 months of age. Polymerase chain reaction (PCR) and HIV cocultivation were of comparable sensitivity, detecting 90% of all positive specimens. Both techniques found positive results in approximately 5% of samples from seroreverting children. Both assays detected HIV in only half of infected newborns, suggesting that this fraction of children was infected during gestation. Plasma p24 antigen was detected in three-fourths of all samples tested but in only half of infected children during the first 2 months of life and 88% of samples from children during the next 4 months. The specificity of p24 antigen detection was 100%.
Similar articles
-
Comparison of a rapid nonisotopic polymerase chain reaction assay with four commonly used methods for the early diagnosis of human immunodeficiency virus type 1 infection in neonates and children.Pediatr Infect Dis J. 1995 Nov;14(11):948-54. doi: 10.1097/00006454-199511000-00005. Pediatr Infect Dis J. 1995. PMID: 8584360
-
A comparative study of virus isolation, polymerase chain reaction, and antigen detection in children of mothers infected with human immunodeficiency virus.J Pediatr. 1990 Mar;116(3):372-6. doi: 10.1016/s0022-3476(05)82823-9. J Pediatr. 1990. PMID: 2308025
-
A novel detection assay for the early diagnosis of HIV-1 infected infants.J Acquir Immune Defic Syndr (1988). 1993 Jun;6(6):582-6. J Acquir Immune Defic Syndr (1988). 1993. PMID: 8388450
-
Measurement of HIV-1 p24 antigen by signal-amplification-boosted ELISA of heat-denatured plasma is a simple and inexpensive alternative to tests for viral RNA.AIDS Rev. 2002 Apr-Jun;4(2):83-92. AIDS Rev. 2002. PMID: 12152521 Review.
-
[Virologic diagnosis of HIV infection in children].Pathol Biol (Paris). 1992 Sep;40(7):720-3. Pathol Biol (Paris). 1992. PMID: 1480408 Review. French.
Cited by
-
Ultrasensitive p24 antigen assay for diagnosis of perinatal human immunodeficiency virus type 1 infection.J Clin Microbiol. 2007 Jul;45(7):2274-7. doi: 10.1128/JCM.00813-07. Epub 2007 May 2. J Clin Microbiol. 2007. PMID: 17475763 Free PMC article.
-
Rapid screening for early detection of mother-to-child transmission of human immunodeficiency virus type 1.J Clin Microbiol. 1994 Nov;32(11):2641-5. doi: 10.1128/jcm.32.11.2641-2645.1994. J Clin Microbiol. 1994. PMID: 7852549 Free PMC article.
-
Prognostic value of immunological data, in vitro antibody production, and virus culture in vertical infection with HIV-1.Arch Dis Child. 1995 Jun;72(6):498-501. doi: 10.1136/adc.72.6.498. Arch Dis Child. 1995. PMID: 7618933 Free PMC article.
-
Effective use of frozen donor peripheral blood mononuclear cells for human immunodeficiency virus type 1 isolation from vertically infected pediatric patients.J Clin Microbiol. 1994 May;32(5):1379-82. doi: 10.1128/jcm.32.5.1379-1382.1994. J Clin Microbiol. 1994. PMID: 8051275 Free PMC article.
-
Flow cytometric immunofluorescence assay for detection of antibodies to human immunodeficiency virus type 1 using insoluble precursor forms of recombinant polyproteins as carriers and antigens.J Clin Microbiol. 1996 Jun;34(6):1412-9. doi: 10.1128/jcm.34.6.1412-1419.1996. J Clin Microbiol. 1996. PMID: 8735090 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical