Neonatal resuscitation: review of ventilation equipment and survey of practice in Australia and New Zealand
- PMID: 15009551
- DOI: 10.1111/j.1440-1754.2004.00339.x
Neonatal resuscitation: review of ventilation equipment and survey of practice in Australia and New Zealand
Abstract
Objective: The equipment used to provide positive pressure ventilation at neonatal resuscitation varies between institutions. Available devices were reviewed and their use surveyed in a geographically defined region. The aim of this study was to establish which resuscitation equipment is used at neonatal intensive care units in Australia and New Zealand.
Methods: A questionnaire was sent to a neonatologist at each of the 29 neonatal intensive care units in Australia and New Zealand, asking which resuscitation equipment they used. If it was not returned, follow up was by email and telephone.
Results: Data was obtained from all units. Round face masks are used at all centres. Anatomically shaped masks are infrequently used at two of the three centres (10%) that have them. Straight endotracheal tubes are used exclusively at 23 (79%) centres. Shouldered tubes are used infrequently at three of the six centres that have them. The Laerdal Infant Resuscitator self-inflating bag is used at 22 (76%) centres. Flow-inflating bags are used at 12 (41%) centres. The Neopuff Infant Resuscitator is used at 14 (48%) centres. Varying oxygen concentrations are provided at delivery at 6/25 (24%) centres.
Conclusions: There is a paucity of evidence for the efficacy of the equipment used currently to resuscitate newborn infants. This complete survey of the tertiary centres in a geographical region shows considerable variation in practice, reflecting this lack of evidence and consequent uncertainty among clinicians. Further research is necessary to determine which devices are preferable for this most important and common intervention.
Similar articles
-
Positive pressure ventilation at neonatal resuscitation: review of equipment and international survey of practice.Acta Paediatr. 2004 May;93(5):583-8. doi: 10.1111/j.1651-2227.2004.tb02981.x. Acta Paediatr. 2004. PMID: 15174776
-
A comparison of three neonatal resuscitation devices.Resuscitation. 2005 Oct;67(1):113-8. doi: 10.1016/j.resuscitation.2005.02.016. Resuscitation. 2005. PMID: 16081202
-
Use of supplementary equipment for resuscitation of newborn infants at tertiary perinatal centres in Australia and New Zealand.Acta Paediatr. 2005 Sep;94(9):1261-5. doi: 10.1111/j.1651-2227.2005.tb02086.x. Acta Paediatr. 2005. PMID: 16278991
-
Comparison of the T-piece resuscitator with other neonatal manual ventilation devices: a qualitative review.Resuscitation. 2012 Jul;83(7):797-802. doi: 10.1016/j.resuscitation.2011.12.020. Epub 2012 Jan 4. Resuscitation. 2012. PMID: 22227500 Review.
-
Resuscitation of premature infants: what are we doing wrong and can we do better?Biol Neonate. 2003;84(1):76-82. doi: 10.1159/000071008. Biol Neonate. 2003. PMID: 12890941 Review.
Cited by
-
Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.Arch Dis Child Fetal Neonatal Ed. 2005 Sep;90(5):F392-6. doi: 10.1136/adc.2004.064691. Epub 2005 May 4. Arch Dis Child Fetal Neonatal Ed. 2005. PMID: 15871989 Free PMC article.
-
Neonatal resuscitation 3: manometer use in a model of face mask ventilation.Arch Dis Child Fetal Neonatal Ed. 2005 Sep;90(5):F397-400. doi: 10.1136/adc.2004.064709. Epub 2005 May 4. Arch Dis Child Fetal Neonatal Ed. 2005. PMID: 15871988 Free PMC article.
-
Sustained versus standard inflations during neonatal resuscitation to prevent mortality and improve respiratory outcomes.Cochrane Database Syst Rev. 2017 Jul 14;7(7):CD004953. doi: 10.1002/14651858.CD004953.pub3. Cochrane Database Syst Rev. 2017. Update in: Cochrane Database Syst Rev. 2020 Mar 18;3:CD004953. doi: 10.1002/14651858.CD004953.pub4. PMID: 28707404 Free PMC article. Updated.
-
Positive end-expiratory pressure for resuscitation of newborn infants at birth.Cochrane Database Syst Rev. 2004 Oct 18;2003(4):CD004341. doi: 10.1002/14651858.CD004341.pub2. Cochrane Database Syst Rev. 2004. PMID: 15495102 Free PMC article.
-
Sustained versus standard inflations during neonatal resuscitation to prevent mortality and improve respiratory outcomes.Cochrane Database Syst Rev. 2020 Mar 18;3(3):CD004953. doi: 10.1002/14651858.CD004953.pub4. Cochrane Database Syst Rev. 2020. Update in: Cochrane Database Syst Rev. 2025 Jul 18;7:CD004953. doi: 10.1002/14651858.CD004953.pub5. PMID: 32187656 Free PMC article. Updated.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical