Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1992 Jul;18(4):333-41.
doi: 10.1016/s0886-3350(13)80067-3.

Effect of posterior chamber intraocular lens design and surgical placement on postoperative outcome

Affiliations
Clinical Trial

Effect of posterior chamber intraocular lens design and surgical placement on postoperative outcome

R G Martin et al. J Cataract Refract Surg. 1992 Jul.

Abstract

Intraocular lens (IOL) design, optical configuration, and placement have potential effects on postoperative outcome. Laboratory studies have suggested that one-piece, biconvex designs may reduce or delay posterior capsular opacification and that in-the-bag fixation of the posterior chamber IOL may reduce inflammation. To document the clinical significance of IOL design and placement, we conducted a randomized, prospective, clinical trial. Six hundred uncomplicated capsulorhexis and phacoemulsification patients were randomized in a three-factor design to receive an IOL that was one-piece or three-piece, had a biconvex, plano-convex, or laser ridge optic, and was bag-or sulcus-fixated. Treatment differences were related to lens placement. Patients with bag-fixated IOLs had less posterior capsular opacification, fewer YAG laser capsulotomies, a higher percentage of centered lenses, less inflammation, and fewer late posterior capsular striae than those with sulcus-fixated IOLs. In the latter group, patients with three-piece IOLs had fewer posterior capsular striae at three months postoperatively. All six occurrences of haptic loop distortion were in patients with three-piece IOLs. Patients with the one-piece design had less late inflammation than those with the three-piece design. Fewer YAG capsulotomies were necessary at one year in patients with the biconvex design than in those with the plano-convex or laser ridge configurations. Operative complications, endothelial cell loss, and postoperative complications were not IOL-related.

PubMed Disclaimer

Publication types

LinkOut - more resources