Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;137(3):420-5.
doi: 10.1016/j.ajo.2003.09.045.

Sensitivity and specificity of the 76-suprathreshold visual field test to detect eyes with visual field defect by Humphrey threshold testing in a population-based setting: the Thessaloniki eye study

Affiliations

Sensitivity and specificity of the 76-suprathreshold visual field test to detect eyes with visual field defect by Humphrey threshold testing in a population-based setting: the Thessaloniki eye study

Fotis Topouzis et al. Am J Ophthalmol. 2004 Mar.

Abstract

Purpose: To evaluate the screening performance of the 76-Suprathreshold (76-STHR) visual field test to detect eyes with visual field defect (VFD) as measured by Humphrey threshold testing in a population-based setting.

Design: Cross-sectional study.

Methods: All 88 subjects who agreed to participate in the pilot phase of the Thessaloniki Eye Study were included. Participants underwent a 76-STHR visual field test followed by a 30-full threshold (30-2 FTHR) test (Humphrey field analyzer). One eye/subject was randomly selected and included in the analysis. Sensitivity and specificity rates of the 76-STHR to detect eyes with VFD by the 30 to 2 FTHR test were calculated.

Results: When eyes with borderline results in the 30 to 2 FTHR test were classified as having a VFD, sensitivity rates of the 76-STHR to detect eyes with VFD by the 30 to 2 FTHR were 85.2%, 77.8%, and 74.1%, whereas specificity rates were 70%, 78%, and 86%, depending on the cutoff used for the 76-STHR.

Conclusions: The 76-STHR test showed high sensitivity and low false-negative results at the "at least one point missed" cutoff level criterion to detect eyes with visual field defect by Humphrey threshold testing in a population-based setting. This criterion should be used when screening in a population-based study setting. By contrast, the 76-STHR would not be the appropriate screening test in a primary care setting with limited resources.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources