Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2004 Mar;125(3):323-8.
doi: 10.1016/j.ajodo.2003.02.007.

Materials-induced variation in the torque expression of preadjusted appliances

Affiliations
Meta-Analysis

Materials-induced variation in the torque expression of preadjusted appliances

Christiana Gioka et al. Am J Orthod Dentofacial Orthop. 2004 Mar.

Abstract

The purpose of this article is to comprehensively investigate the sources of variation in the expression of torque in preadjusted appliances. Variables related to properties of materials were systematically analyzed, including (1) the inability to fill the slot because of the size difference of archwires and bracket slot, (2) irregularities from the manufacturing process of brackets precluding proper engagement, (3) differences in the stiffness of wire alloys engaged to the bracket slot, (4) variations between actual and reported bracket torque values, and (5) ligation modes, all of which might account for increased third-order clearance or bracket-archwire "play." The effect of these variations on the expression of torque is discussed, and the net buccolingual inclinations are provided as a function of wire size and composition for common bracket slot-archwire combinations. Most reports published on this issue indicate a loss of torque control as high as 100% of the prescribed value. Furthermore, the fallacy of transferring the ideal crown inclination to the torque prescribed in the bracket is illustrated, along with the underestimation of the prescribed torque relative to the proper tooth crown. The realistically required torque is analyzed to its constituent components, involving tooth inclination, compensation for the slot-wire play, and incomplete ligation with elastomeric ligatures. Based on the evidence available, it is proposed that a high-torque prescription should be selected to account for the lack of full expression of the prescribed torque that occurs clinically.

PubMed Disclaimer

Comment in

  • Variation in torque expression.
    Cordato M. Cordato M. Am J Orthod Dentofacial Orthop. 2004 Jul;126(1):18A; author reply 19A. doi: 10.1016/j.ajodo.2004.05.004. Am J Orthod Dentofacial Orthop. 2004. PMID: 15264362 No abstract available.
  • Torque variation in preadjusted appliances.
    Speck M. Speck M. Am J Orthod Dentofacial Orthop. 2004 Aug;126(2):18A. doi: 10.1016/j.ajodo.2004.06.021. Am J Orthod Dentofacial Orthop. 2004. PMID: 15318418 No abstract available.
  • Variation in torque expression in preadjusted appliances.
    De Angelis V, Davidovitch Z. De Angelis V, et al. Am J Orthod Dentofacial Orthop. 2004 Nov;126(5):20A; author reply 21A-22A. Am J Orthod Dentofacial Orthop. 2004. PMID: 15568231 No abstract available.

Publication types