Abstract
The objectives of this study were to evaluate and compare the shear bond strengths and bond failure locations of 2 currently available orthodontic ceramic brackets. Forty polycrystalline ceramic brackets (Clarity, 3M Unitek, Monrovia, Calif) and 40 monocrystalline ceramic brackets (Inspire, Ormco, Orange, Calif) were bonded to 80 extracted premolars with the same bonding system. All bonded specimens were placed in distilled water for 42 hours at 37 degrees C followed by thermal cycling for 700 complete cycles. Forty ceramic brackets, 20 of each type, were tested on a universal testing machine to determine the shear force levels required to debond them. Forty ceramic brackets were removed with the debonding pliers recommended by the manufacturers. All teeth were examined under an optical microscope, and the adhesive remnant index was used to assess the bond failure locations. The mean shear bond strength of the Clarity brackets was 21.67 +/- 5.19 MPa, and the mean shear bond strength of the Inspire brackets was 20.32 +/- 8 MPa. The mean shear bond strengths of both brackets were higher than those considered clinically optimal. Most of the brackets (85% of Clarity and 75% of Inspire) tested on the machine failed at the bracket-adhesive interface. One premolar bonded with an Inspire bracket had enamel fracture upon debonding. Most of the brackets (90% of Clarity and 95% of Inspire) debonded with pliers failed at the bracket-adhesive interface. No enamel damage was evident in any specimen when the brackets were removed with the appropriate pliers. The results indicate that the safest way to remove ceramic brackets with respect to reducing the chance of enamel damage is to use the debonding technique specifically designed for each.
Similar articles
-
Effects of different debonding techniques on the debonding forces and failure modes of ceramic brackets in simulated clinical set-ups.Am J Orthod Dentofacial Orthop. 2007 Nov;132(5):680-6. doi: 10.1016/j.ajodo.2006.01.035. Am J Orthod Dentofacial Orthop. 2007. PMID: 18005844
-
Bond strength and debonding characteristics of a new ceramic bracket.Am J Orthod Dentofacial Orthop. 2005 Dec;128(6):761-5; quiz 802. doi: 10.1016/j.ajodo.2004.03.041. Am J Orthod Dentofacial Orthop. 2005. PMID: 16360918
-
Comparison of the debonding characteristics of two innovative ceramic bracket designs.Am J Orthod Dentofacial Orthop. 1999 Jul;116(1):86-92. doi: 10.1016/s0889-5406(99)70307-0. Am J Orthod Dentofacial Orthop. 1999. PMID: 10393585
-
Effect of varying etching times on the bond strength of ceramic brackets.Am J Orthod Dentofacial Orthop. 1996 Apr;109(4):403-9. doi: 10.1016/s0889-5406(96)70122-1. Am J Orthod Dentofacial Orthop. 1996. PMID: 8638582 Review.
-
In-vivo and in-vitro comparison of bond strengths of orthodontic brackets bonded to enamel and debonded at various times.Am J Orthod Dentofacial Orthop. 2007 Mar;131(3):384-90. doi: 10.1016/j.ajodo.2005.06.025. Am J Orthod Dentofacial Orthop. 2007. PMID: 17346595 Review.
Cited by
-
Do dental bleaching sessions prior to orthodontic treatment change the bond strength of esthetic brackets?Dental Press J Orthod. 2021 Aug 27;26(4):e2119124. doi: 10.1590/2177-6709.26.4.e2119124.oar. eCollection 2021. Dental Press J Orthod. 2021. PMID: 34468559 Free PMC article.
-
A Comparison of Shear Bond Strengths of Metal and Ceramic Brackets using Conventional Acid Etching Technique and Er:YAG Laser Etching.J Dent Res Dent Clin Dent Prospects. 2014 Winter;8(1):27-34. doi: 10.5681/joddd.2014.005. Epub 2014 Mar 5. J Dent Res Dent Clin Dent Prospects. 2014. PMID: 25024836 Free PMC article.
-
Evaluation of stresses developed in different bracket-cement-enamel systems using finite element analysis with in vitro bond strength tests.Prog Orthod. 2014 Apr 16;15(1):33. doi: 10.1186/s40510-014-0033-1. Prog Orthod. 2014. PMID: 24934213 Free PMC article.
-
Finite element study on modification of bracket base and its effects on bond strength.Dental Press J Orthod. 2015 Mar-Apr;20(2):76-82. doi: 10.1590/2176-9451.20.2.076-082.oar. Dental Press J Orthod. 2015. PMID: 25992991 Free PMC article.
-
Effect of the different debonding strength of metal and ceramic brackets on the degree of enamel microcrack healing.Dental Press J Orthod. 2021 Jun 25;26(3):e2119177. doi: 10.1590/2177-6709.26.3.e2119177.oar. eCollection 2021. Dental Press J Orthod. 2021. PMID: 34190770 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources