Distributions-per-level: a means of testing level detectors and models of patch-clamp data
Abstract
Level or jump detectors generate the reconstructed time series from a noisy record of patch-clamp current. The reconstructed time series is used to create dwell-time histograms for the kinetic analysis of the Markov model of the investigated ion channel. It is shown here that some additional lines in the software of such a detector can provide a powerful new means of patch-clamp analysis. For each current level that can be recognized by the detector, an array is declared. The new software assigns every data point of the original time series to the array that belongs to the actual state of the detector. From the data sets in these arrays distributions-per-level are generated. Simulated and experimental time series analyzed by Hinkley detectors are used to demonstrate the benefits of these distributions-per-level. First, they can serve as a test of the reliability of jump and level detectors. Second, they can reveal beta distributions as resulting from fast gating that would usually be hidden in the overall amplitude histogram. Probably the most valuable feature is that the malfunctions of the Hinkley detectors turn out to depend on the Markov model of the ion channel. Thus, the errors revealed by the distributions-per-level can be used to distinguish between different putative Markov models of the measured time series.
Similar articles
-
A new level detector for ion channel analysis.J Membr Biol. 2002 Sep 15;189(2):105-18. doi: 10.1007/s00232-002-1011-y. J Membr Biol. 2002. PMID: 12235486
-
A chi(2) test for model determination and sublevel detection in ion channel analysis.J Membr Biol. 2002 Jan 1;185(1):25-41. doi: 10.1007/s00232-001-0107-0. Epub 2002 Jan 13. J Membr Biol. 2002. PMID: 11891562
-
Restoration of single-channel currents using the segmental k-means method based on hidden Markov modeling.Biophys J. 2004 Mar;86(3):1488-501. doi: 10.1016/S0006-3495(04)74217-4. Biophys J. 2004. PMID: 14990476 Free PMC article.
-
Principles of single-channel kinetic analysis.Methods Mol Biol. 2007;403:253-86. doi: 10.1007/978-1-59745-529-9_17. Methods Mol Biol. 2007. PMID: 18828000 Review.
-
How to resolve microsecond current fluctuations in single ion channels: the power of beta distributions.Channels (Austin). 2015;9(5):262-80. doi: 10.1080/19336950.2015.1083660. Channels (Austin). 2015. PMID: 26368656 Free PMC article. Review.
Cited by
-
Modulation of enrofloxacin binding in OmpF by Mg2+ as revealed by the analysis of fast flickering single-porin current.J Gen Physiol. 2012 Jul;140(1):69-82. doi: 10.1085/jgp.201210776. Epub 2012 Jun 11. J Gen Physiol. 2012. PMID: 22689827 Free PMC article.
-
Tl+-induced micros gating of current indicates instability of the MaxiK selectivity filter as caused by ion/pore interaction.J Gen Physiol. 2008 Apr;131(4):365-78. doi: 10.1085/jgp.200809956. J Gen Physiol. 2008. PMID: 18378799 Free PMC article.
-
Statistical assessment of change point detectors for single molecule kinetic analysis.J Membr Biol. 2013 May;246(5):407-20. doi: 10.1007/s00232-013-9553-8. Epub 2013 May 8. J Membr Biol. 2013. PMID: 23652811
-
Saturation and microsecond gating of current indicate depletion-induced instability of the MaxiK selectivity filter.J Gen Physiol. 2007 Jul;130(1):83-97. doi: 10.1085/jgp.200709802. J Gen Physiol. 2007. PMID: 17591987 Free PMC article.
-
Test of normality for integrated change point detection and mixture modeling.J Membr Biol. 2013 Jan;246(1):57-66. doi: 10.1007/s00232-012-9504-9. Epub 2012 Oct 16. J Membr Biol. 2013. PMID: 23070527
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources