Abstract
It is estimated that in excess of one million positron emission tomography (PET) scans are performed each year and PET can now truly be regarded as a routine imaging procedure in clinical management. Many potential pitfalls and artifacts have previously been described with (18)F-fluorodeoxyglucose PET imaging, but more continue to become apparent as worldwide experience increases. In addition, the advent of combined PET/CT scanners in clinical imaging practice has brought their own specific pitfalls and artifacts. It is essential that we learn these potential pitfalls so that patients can be optimally prepared for their scans and that accurate interpretation can be made.
Similar articles
-
Pitfalls in PET/CT interpretation.Q J Nucl Med Mol Imaging. 2007 Sep;51(3):235-43. Q J Nucl Med Mol Imaging. 2007. PMID: 17464270 Review.
-
[Positron-emission tomography/computed tomography: artifacts and pitfalls in cancer patients].Radiologia. 2006 Jul-Aug;48(4):189-204. doi: 10.1016/s0033-8338(06)73156-3. Radiologia. 2006. PMID: 17058646 Review. Spanish.
-
Artifacts at PET and PET/CT caused by metallic hip prosthetic material.Radiology. 2003 Feb;226(2):577-84. doi: 10.1148/radiol.2262012141. Radiology. 2003. PMID: 12563158
-
Positron emission tomography/computed tomography.Semin Nucl Med. 2008 May;38(3):152-66. doi: 10.1053/j.semnuclmed.2008.01.003. Semin Nucl Med. 2008. PMID: 18396176 Review.
-
PET/CT Interpretative Pitfalls in Thoracic Malignancies.Semin Ultrasound CT MR. 2018 Jun;39(3):282-288. doi: 10.1053/j.sult.2018.02.007. Epub 2018 Mar 8. Semin Ultrasound CT MR. 2018. PMID: 29807638 Review.
Cited by
-
Photon quantum entanglement in the MeV regime and its application in PET imaging.Nat Commun. 2021 May 11;12(1):2646. doi: 10.1038/s41467-021-22907-5. Nat Commun. 2021. PMID: 33976168 Free PMC article.
-
Cancer in Patients With Incidental Asymmetric Oropharynx Positron Emission Tomography Uptake.JAMA Otolaryngol Head Neck Surg. 2024 Dec 1;150(12):1078-1086. doi: 10.1001/jamaoto.2024.2556. JAMA Otolaryngol Head Neck Surg. 2024. PMID: 39207815
-
Respiratory motion artefact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source.Eur J Nucl Med Mol Imaging. 2005 Dec;32(12):1422-8. doi: 10.1007/s00259-005-1868-y. Epub 2005 Aug 31. Eur J Nucl Med Mol Imaging. 2005. PMID: 16133387 Clinical Trial.
-
Artificial Intelligence-Driven Single-Shot PET Image Artifact Detection and Disentanglement: Toward Routine Clinical Image Quality Assurance.Clin Nucl Med. 2023 Dec 1;48(12):1035-1046. doi: 10.1097/RLU.0000000000004912. Epub 2023 Oct 25. Clin Nucl Med. 2023. PMID: 37883015 Free PMC article.
-
Positron emission tomography/computed tomography hypermetabolism of Kikuchi-Fujimoto disease mimicking malignant lymphoma: a case report and literature review.J Int Med Res. 2021 Jul;49(7):3000605211032859. doi: 10.1177/03000605211032859. J Int Med Res. 2021. PMID: 34334002 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical