Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;112(4):480-7.
doi: 10.1289/ehp.6694.

Dye bias correction in dual-labeled cDNA microarray gene expression measurements

Affiliations

Dye bias correction in dual-labeled cDNA microarray gene expression measurements

Barry A Rosenzweig et al. Environ Health Perspect. 2004 Mar.

Abstract

A significant limitation to the analytical accuracy and precision of dual-labeled spotted cDNA microarrays is the signal error due to dye bias. Transcript-dependent dye bias may be due to gene-specific differences of incorporation of two distinctly different chemical dyes and the resultant differential hybridization efficiencies of these two chemically different targets for the same probe. Several approaches were used to assess and minimize the effects of dye bias on fluorescent hybridization signals and maximize the experimental design efficiency of a cell culture experiment. Dye bias was measured at the individual transcript level within each batch of simultaneously processed arrays by replicate dual-labeled split-control sample hybridizations and accounted for a significant component of fluorescent signal differences. This transcript-dependent dye bias alone could introduce unacceptably high numbers of both false-positive and false-negative signals. We found that within a given set of concurrently processed hybridizations, the bias is remarkably consistent and therefore measurable and correctable. The additional microarrays and reagents required for paired technical replicate dye-swap corrections commonly performed to control for dye bias could be costly to end users. Incorporating split-control microarrays within a set of concurrently processed hybridizations to specifically measure dye bias can eliminate the need for technical dye swap replicates and reduce microarray and reagent costs while maintaining experimental accuracy and technical precision. These data support a practical and more efficient experimental design to measure and mathematically correct for dye bias.

PubMed Disclaimer

References

    1. J Comput Biol. 2001;8(6):625-37 - PubMed
    1. Nucleic Acids Res. 2002 Feb 15;30(4):e15 - PubMed
    1. Cancer Res. 2002 Mar 15;62(6):1688-95 - PubMed
    1. Nat Genet. 2002 Dec;32 Suppl:496-501 - PubMed
    1. J Comput Biol. 2001;8(4):443-61 - PubMed

Publication types

MeSH terms

LinkOut - more resources