Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Apr 6;109(13):1630-5.
doi: 10.1161/01.CIR.0000124221.84399.48. Epub 2004 Mar 22.

Lower loop reentry as a mechanism of clockwise right atrial flutter

Affiliations

Lower loop reentry as a mechanism of clockwise right atrial flutter

Shulong Zhang et al. Circulation. .

Abstract

Background: Right atrial reentrant tachycardia resulting from lower loop reentry (LLR) around the inferior vena cava (IVC) has been described recently. However, all reported cases of LLR in the literature have negative flutter waves on the inferior surface ECG leads similar to that of counterclockwise typical atrial flutter around the tricuspid annulus (TA). Right atrial flutter with positive flutter waves in the inferior ECG leads has been assumed to rotate as a single reentrant activation wave front around the TA, and the role of LLR in those patients is not known.

Methods and results: Twelve consecutive patients with flutter wave morphology on surface ECG consistent with clockwise atrial flutter were studied. The endocardial activation pattern recorded from conventional multipolar electrode catheters was characteristic of clockwise atrial flutter around the TA. Entrainment pacing in all 12 patients and 3D activation sequence mapping in 7 patients, however, revealed clockwise LLR involving the lower right atrium around the IVC in 7 patients, figure-of-8 double-loop reentry around both the IVC and TA in 4, and single reentrant loop around the TA in 1. Linear radiofrequency ablation in the isthmus between the TA and IVC (TI isthmus) terminated the tachycardia in all patients.

Conclusions: Surface ECG flutter wave morphology and limited recording intracardiac sites proved insufficient to delineate the precise mechanism of the TI isthmus-dependent clockwise right atrial flutters. Most right atrial flutters with positive flutter wave on surface ECG may be supported by a reentrant circuit around the IVC or a figure-of-8 double-loop reentry involving both the IVC and TA.

PubMed Disclaimer

Publication types

LinkOut - more resources