The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
- PMID: 15045170
- DOI: 10.1007/s00134-004-2233-5
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Abstract
Objective: To investigate whether the respiratory variation in inferior vena cava diameter (DeltaD(IVC)) could be related to fluid responsiveness in mechanically ventilated patients.
Design: Prospective clinical study.
Setting: Medical ICU of a non-university hospital.
Patients: Mechanically ventilated patients with septic shock (n=39).
Interventions: Volume loading with 8 mL/kg of 6% hydroxyethylstarch over 20 min.
Measurements and results: Cardiac output and DeltaD(IVC) were assessed by echography before and immediately after the standardized volume load. Volume loading induced an increase in cardiac output from 5.7+/-2.0 to 6.4+/-1.9 L/min (P<0.001) and a decrease in DeltaD(IVC) from 13.8+/-13.6 vs 5.2+/-5.8% (P<0.001). Sixteen patients responded to volume loading by an increase in cardiac output > or =15% (responders). Before volume loading, the DeltaD(IVC) was greater in responders than in non-responders (25+/-15 vs 6+/-4%, P<0.001), closely correlated with the increase in cardiac output (r=0.82, P<0.001), and a 12% DeltaD(IVC) cut-off value allowed identification of responders with positive and negative predictive values of 93% and 92%, respectively.
Conclusion: Analysis of DeltaD(IVC) is a simple and non-invasive method to detect fluid responsiveness in mechanically ventilated patients with septic shock.
Comment in
-
Evaluation of fluid responsiveness in ventilated septic patients: back to venous return.Intensive Care Med. 2004 Sep;30(9):1699-701. doi: 10.1007/s00134-004-2362-x. Epub 2004 Jun 25. Intensive Care Med. 2004. PMID: 15221127 No abstract available.
Similar articles
-
Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.Crit Care. 2014 Sep 5;18(5):473. doi: 10.1186/s13054-014-0473-5. Crit Care. 2014. PMID: 25189403 Free PMC article.
-
The Value of the Inferior Vena Cava Area Distensibility Index and its Diameter Ratio for Predicting Fluid Responsiveness in Mechanically Ventilated Patients.Shock. 2019 Jul;52(1):37-42. doi: 10.1097/SHK.0000000000001238. Shock. 2019. PMID: 31188800
-
Bedside ultrasonographic measurement of the inferior vena cava fails to predict fluid responsiveness in the first 6 hours after cardiac surgery: a prospective case series observational study.J Cardiothorac Vasc Anesth. 2015;29(3):663-9. doi: 10.1053/j.jvca.2014.08.015. Epub 2014 Dec 23. J Cardiothorac Vasc Anesth. 2015. PMID: 25541507
-
Accuracy of Ultrasonographic Measurements of Inferior Vena Cava to Determine Fluid Responsiveness: A Systematic Review and Meta-Analysis.J Intensive Care Med. 2020 Apr;35(4):354-363. doi: 10.1177/0885066617752308. Epub 2018 Jan 17. J Intensive Care Med. 2020. PMID: 29343170
-
Value of variation index of inferior vena cava diameter in predicting fluid responsiveness in patients with circulatory shock receiving mechanical ventilation: a systematic review and meta-analysis.Crit Care. 2018 Aug 21;22(1):204. doi: 10.1186/s13054-018-2063-4. Crit Care. 2018. PMID: 30126449 Free PMC article.
Cited by
-
Predicting and measuring fluid responsiveness with echocardiography.Echo Res Pract. 2016 Jun;3(2):G1-G12. doi: 10.1530/ERP-16-0008. Epub 2016 May 24. Echo Res Pract. 2016. PMID: 27249550 Free PMC article.
-
Echocardiographic hemodynamic monitoring in the critically ill patient.Curr Cardiol Rev. 2011 Aug;7(3):146-56. doi: 10.2174/157340311798220485. Curr Cardiol Rev. 2011. PMID: 22758613 Free PMC article. Review.
-
Evaluation of caudal vena cava size using computed tomography in dogs under general anesthesia.J Vet Med Sci. 2022 Nov 18;84(12):1556-1562. doi: 10.1292/jvms.22-0122. Epub 2022 Oct 14. J Vet Med Sci. 2022. PMID: 36244742 Free PMC article.
-
The effect of continuous positive airway pressure on inferior vena cava collapsibility as measured by bedside ultrasound.J Am Coll Emerg Physicians Open. 2022 Dec 1;3(6):e12856. doi: 10.1002/emp2.12856. eCollection 2022 Dec. J Am Coll Emerg Physicians Open. 2022. PMID: 36474708 Free PMC article.
-
Mitral valve velocity time integral and passive leg raise as a measure of volume responsiveness.Crit Ultrasound J. 2018 Dec 2;10(1):32. doi: 10.1186/s13089-018-0114-3. Crit Ultrasound J. 2018. PMID: 30506432 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical