Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Feb;99(2):280-5.
doi: 10.1111/j.1572-0241.2004.04056.x.

Polytetrafluoroethylene-covered stent grafts for TIPS procedure: 1-year patency and clinical results

Affiliations
Clinical Trial

Polytetrafluoroethylene-covered stent grafts for TIPS procedure: 1-year patency and clinical results

Stefania Angeloni et al. Am J Gastroenterol. 2004 Feb.

Abstract

Objectives: Polytetrafluoroethylene (PTFE)-covered stent grafts appear to have the potential to improve TIPS patency, but data available are few and controversial. The aim of this prospective nonrandomized trial was to assess TIPS safety and 1-yr patency with a new commercially available PTFE-covered stent graft in comparison with a group of historical controls treated with conventional stents.

Methods: Between July 1992 and December 1999, 87 consecutive cirrhotics underwent TIPS with conventional stents, while from January 2000 to November 2001, 32 consecutive cirrhotics were treated with PTFE-covered stent grafts. All patients were followed by the same medical team according to a prospective protocol for a diagnostic work-up and a surveillance strategy.

Results: The two groups were comparable for age, sex, etiology, and severity of cirrhosis. The 1-yr probability of remaining free of shunt dysfunction tended to be higher in the covered stent group: 76.3% (95% CI = 58.7-93.9%) versus 57.5% (95% CI = 46.6-68.4%); log rank test: p = 0.055. However, stenoses inside the stent were significantly higher in patients with bare stents (88% vs 17%), while stenoses at the hepatic or portal vein were more frequent in PTFE-covered stent-graft group (50% vs 9% and 33% vs 3%, respectively), (chi2 = 15.42; df = 2.0; p = 0.0004). Stenoses inside the covered portion of the stent did not occur. One-year cumulative rebleeding, encephalopathy, and survival were similar.

Conclusions: PTFE-covered stents are able to solve pseudointimal hyperplasia within the stent tract, but have a high incidence of hepatic or portal vein stenosis. Improvements in stent design and insertion techniques are necessary to fully achieve the potential benefit of this new device.

PubMed Disclaimer

Publication types

MeSH terms

Substances