Estimating localized oscillatory tissue motion for assessment of the underlying mechanical modulus
Abstract
The technique of harmonic motion imaging (HMI) uses the localized stimulus of the oscillatory ultrasonic radiation force as produced by two overlapping beams of distinct frequencies, and estimates the resulting harmonic displacement in the tissue in order to assess its underlying mechanical properties. In this paper, we studied the relationship between measured displacement and stiffness in gels and tissues in vitro. Two focused ultrasound transducers with a 100 mm focal length were used at frequencies of 3.7500 MHz and either 3.7502 (or 3.7508 MHz), respectively, in order to produce an oscillatory motion at 200 Hz in the gel or tissue. A 1.1 MHz diagnostic transducer (Imasonics, Inc.) was also focused at 100 mm and acquired 5 ms RF signals (pulse repetition frequency (PRF)=3.5 kHz) at 100 MHz sampling frequency during radiation force application. First, three 50x50 mm(2) acrylamide gels were prepared at concentrations of 4%, 8% and 16%. The resulting displacement was estimated using crosscorrelation techniques between successively acquired RF signals with a 2 mm window and 80% window overlap at 1260 W/cm(2). A normal 1-D indentation instrument (TeMPeST) applied oscillatory loads at 0.1-200 Hz with a 5 mm-diameter flat indenter. Then, 12 displacement measurements in 6 porcine muscle specimens (two measurements/case, as above) were made in vitro, before and after ablation which was performed for 10 s at 1260 W/cm(2). In all gel cases, the harmonic displacement was found to linearly increase with intensity and exponentially decrease with gel concentration. The TeMPeST measurements showed that the elastic moduli for the 4%, 8% and 16% gels equaled 3.93+/-0.06, 17.1+/-0.2 and 75+/-2 kPa, respectively, demonstrating that the HMI displacement estimate depends directly on the gel stiffness. Finally, in the tissues samples, the mean displacement amplitude showed a twofold decrease between non-ablated and ablated tissue, demonstrating a correspondence between the HMI response and an increase in stiffness measured with the TeMPeST instrument.
Similar articles
-
Localized harmonic motion imaging: theory, simulations and experiments.Ultrasound Med Biol. 2003 Oct;29(10):1405-13. doi: 10.1016/s0301-5629(03)00953-0. Ultrasound Med Biol. 2003. PMID: 14597337
-
Single-element focused ultrasound transducer method for harmonic motion imaging.Ultrason Imaging. 2006 Jul;28(3):144-58. doi: 10.1177/016173460602800302. Ultrason Imaging. 2006. PMID: 17147056
-
Simulation study of amplitude-modulated (AM) harmonic motion imaging (HMI) for stiffness contrast quantification with experimental validation.Ultrason Imaging. 2010 Jul;32(3):154-76. doi: 10.1177/016173461003200304. Ultrason Imaging. 2010. PMID: 20718245
-
Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues.Phys Med Biol. 2008 Mar 21;53(6):1773-93. doi: 10.1088/0031-9155/53/6/018. Epub 2008 Mar 7. Phys Med Biol. 2008. PMID: 18367802
-
Tissue deformation induced by radiation force from Gaussian transducers.J Acoust Soc Am. 2006 May;119(5 Pt 1):3147-52. doi: 10.1121/1.2187087. J Acoust Soc Am. 2006. PMID: 16708969 Review.
Cited by
-
Image quality, tissue heating, and frame rate trade-offs in acoustic radiation force impulse imaging.IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Jan;56(1):63-76. doi: 10.1109/TUFFC.2009.1006. IEEE Trans Ultrason Ferroelectr Freq Control. 2009. PMID: 19213633 Free PMC article.
-
Harmonic motion imaging for abdominal tumor detection and high-intensity focused ultrasound ablation monitoring: an in vivo feasibility study in a transgenic mouse model of pancreatic cancer.IEEE Trans Ultrason Ferroelectr Freq Control. 2015 Sep;62(9):1662-73. doi: 10.1109/TUFFC.2015.007113. IEEE Trans Ultrason Ferroelectr Freq Control. 2015. PMID: 26415128 Free PMC article.
-
Harmonic motion detection in a vibrating scattering medium.IEEE Trans Ultrason Ferroelectr Freq Control. 2008 Sep;55(9):1956-74. doi: 10.1109/TUFFC.887. IEEE Trans Ultrason Ferroelectr Freq Control. 2008. PMID: 18986892 Free PMC article.
-
AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.Curr Med Imaging Rev. 2011 Nov;7(4):255-282. doi: 10.2174/157340511798038684. Curr Med Imaging Rev. 2011. PMID: 22308105 Free PMC article.
-
A new Tissue Resonator Indenter Device and reliability study.Sensors (Basel). 2011;11(1):1212-28. doi: 10.3390/s110101212. Epub 2011 Jan 20. Sensors (Basel). 2011. PMID: 22346623 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources