Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;30(3):584-90.
doi: 10.1016/j.jcrs.2003.07.009.

Cataract surgery in patients with nanophthalmos: results and complications

Affiliations

Cataract surgery in patients with nanophthalmos: results and complications

Wayne Wu et al. J Cataract Refract Surg. 2004 Mar.

Abstract

Purpose: To evaluate the results and complications of cataract surgery in patients with nanophthalmos.

Setting: University hospital practice.

Methods: The records of consecutive patients with nanophthalmos who had cataract surgery from 1978 through 2002 were reviewed for ocular diagnoses, corneal diameter, keratometry, axial length, retinal-choroidal-scleral thickness determined by echography, ocular surgeries, visual acuity, and complications.

Results: Eight patients (6 women, 2 men) with a mean age of 59 years were reviewed. Four patients were not previously diagnosed with nanophthalmos; increased retinal-choroidal-scleral thickness (mean 2.41 mm) confirmed the diagnosis. Twelve eyes had cataract extraction with posterior chamber intraocular lens (IOL) implantation, 11 by phacoemulsification and 1 by extracapsular cataract extraction, and 4 eyes had lamellar scleral resections. Additional surgeries included glaucoma laser treatment (8 eyes), cyclocryotherapy (2 eyes), trabeculectomy with scleral resection (1 eye), trabeculectomy combined with phacoemulsification (1 eye), and neodymium:YAG laser capsulotomy (4 eyes). No eye lost vision; however, complications included severe iritis, broken IOL haptic with vitreous loss, posterior capsule opacity, choroidal hemorrhage, phthisis, and aqueous misdirection.

Conclusions: Results indicate that echography should be used to assess retinal-choroidal-scleral thickness in eyes that are hyperopic and at risk for narrow-angle glaucoma. Thickening may confirm the diagnosis of nanophthalmos and allow careful preoperative assessment and appropriate operative procedures in these high-risk eyes. With advances in cataract, glaucoma, and uveal effusion treatments, surgical results in patients with nanophthalmos are improving.

PubMed Disclaimer

Publication types

MeSH terms