Cortical bone in the human femoral neck: three-dimensional appearance and porosity using synchrotron radiation
- PMID: 15068503
- DOI: 10.1359/JBMR.040124
Cortical bone in the human femoral neck: three-dimensional appearance and porosity using synchrotron radiation
Abstract
A high-resolution CT system using synchrotron radiation allowed visualization of the 3D cortical bone microarchitecture and measurement of intracortical porosity of femoral neck cortical bone specimens from 19 female cadavers imaged at 10.13-microm resolution. 3D reconstruction of specimens showed osteonal system arrangement. Mean porosity was 15.88%. This technique will provide insights into the mechanisms involved in osteoporotic hip fractures.
Introduction: The purpose of this study was to show that a high-resolution CT system using synchrotron radiation (SR) allows visualization of the 3D cortical bone microarchitecture of the human femoral neck and quantification of intracortical porosity.
Materials and methods: Bone specimens from the inferior femoral neck were obtained from 19 female cadavers with no hip fracture (mean, 86.9 +/- 8.3 years). The specimens, consisting of embedded approximately 7 x 7 x 12-mm cortical bone parallelepipeds, were imaged using SR at 10.13-microm resolution. Commercial software was used to visualize both the 660 x 660 x 660-voxel volumes and the 2D axial slices through each volume. Qualitative examination of 2D axial slices focused on the appearance of the vessel canal system, presence of small bright zones (fully mineralized tissue) in the osseous matrix, and presence of cracks. A method was developed to automatically measure 3D intracortical porosity after separating pure bone from pores and cortical bone from trabecular bone.
Results and conclusions: 3D reconstruction of the specimens showed the entire structure and arrangement of the osteonal systems, parallel to the axis of the femoral neck. Bright zones were seen in the outer cortex. No cracks were observed. Porosity values varied widely from 4.96% to 38.87% (mean, 15.88 +/- 9.87%). This study establishes that SR microtomography can be used to display the 3D bone microstructure of the human femoral neck cortex and to quantify intracortical porosity. This technique will provide insights into the mechanisms involved in cortical bone loss and osteoporotic hip fractures.
Similar articles
-
Cortical Bone Porosity: What Is It, Why Is It Important, and How Can We Detect It?Curr Osteoporos Rep. 2016 Oct;14(5):187-98. doi: 10.1007/s11914-016-0319-y. Curr Osteoporos Rep. 2016. PMID: 27623679 Review.
-
Age- and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck.Osteoporos Int. 2010 Apr;21(4):627-36. doi: 10.1007/s00198-009-0993-z. Epub 2009 Jun 19. Osteoporos Int. 2010. PMID: 19543764
-
Time-lapsed assessment of microcrack initiation and propagation in murine cortical bone at submicrometer resolution.Bone. 2009 Aug;45(2):164-73. doi: 10.1016/j.bone.2009.04.248. Epub 2009 May 3. Bone. 2009. PMID: 19410668
-
Regional Heterogeneity in the Configuration of the Intracortical Canals of the Femoral Shaft.Calcif Tissue Int. 2015 Oct;97(4):327-35. doi: 10.1007/s00223-015-0014-5. Epub 2015 Jun 7. Calcif Tissue Int. 2015. PMID: 26050153
-
High resolution imaging in bone tissue research-review.Bone. 2021 Feb;143:115620. doi: 10.1016/j.bone.2020.115620. Epub 2020 Aug 29. Bone. 2021. PMID: 32866682 Review.
Cited by
-
Measurement of bound and pore water T1 relaxation times in cortical bone using three-dimensional ultrashort echo time cones sequences.Magn Reson Med. 2017 Jun;77(6):2136-2145. doi: 10.1002/mrm.26292. Epub 2016 Jun 6. Magn Reson Med. 2017. PMID: 27263994 Free PMC article.
-
High-Resolution X-Ray Tomography: A 3D Exploration Into the Skeletal Architecture in Mouse Models Submitted to Microgravity Constraints.Front Physiol. 2018 Mar 6;9:181. doi: 10.3389/fphys.2018.00181. eCollection 2018. Front Physiol. 2018. PMID: 29593553 Free PMC article. Review.
-
Towards assessing cortical bone porosity using low-frequency quantitative acoustics: A phantom-based study.PLoS One. 2017 Sep 7;12(9):e0182617. doi: 10.1371/journal.pone.0182617. eCollection 2017. PLoS One. 2017. PMID: 28880868 Free PMC article.
-
Cortical Bone Porosity: What Is It, Why Is It Important, and How Can We Detect It?Curr Osteoporos Rep. 2016 Oct;14(5):187-98. doi: 10.1007/s11914-016-0319-y. Curr Osteoporos Rep. 2016. PMID: 27623679 Review.
-
The Application of Advanced Bone Imaging Technologies in Sports Medicine.Radiol Res Pract. 2023 Dec 4;2023:7412540. doi: 10.1155/2023/7412540. eCollection 2023. Radiol Res Pract. 2023. PMID: 38090470 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials