Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Mar;22(3):511-7.
doi: 10.1097/00004872-200403000-00013.

Validity of pulse pressure and augmentation index as surrogate measures of arterial stiffness during beta-adrenergic stimulation

Affiliations
Clinical Trial

Validity of pulse pressure and augmentation index as surrogate measures of arterial stiffness during beta-adrenergic stimulation

Daniel Lemogoum et al. J Hypertens. 2004 Mar.

Abstract

Objective: Increased arterial stiffness is a determinant of cardiovascular mortality. Pulse wave velocity (PWV) is a direct measure of arterial stiffness. Aortic augmentation index (AI) and pulse pressure (PP) are surrogate measures of arterial stiffness. Both PWV, AI and PP increase with cardiovascular risk factors. The aim of this study was to test the validity of AI and PP as surrogate measures of arterial stiffness compared with PWV, during beta-adrenergic stimulation with Isoprenaline (Iso).

Design and methods: A total of 41 healthy volunteers entered a randomized, double-blind, placebo-controlled, cross-over study. In random order, subjects were given intravenous infusion in equal volume of Iso 8 microg/kg per min (dissolved in glucose 5%) and placebo (glucose 5%). A wash-out period of 25 min was observed between the infusions. Measurements included blood pressure (BP), heart rate (HR), PWV, and AI. PWV were determined using complior (Complior, Artech-Medical, Paris, France). AI and aortic PP were obtained from pulse wave analysis of radial applanation tonometry, using transfer function (SphygmoCor Windows software).

Results: Baseline AI increased (P < 0.05) with aging, a lower height and a larger diastolic BP (DBP). Iso increased (P < 0.0001) HR, brachial SBP, brachial and aortic PP as compared with placebo. In contrast, Iso decreased (P < 0.05) AI, brachial DBP, peripheral PWV, but not aortic PWV. Decrease of AI induced by Iso was not related to PWV. In stepwise multiple regression changes in HR, brachial SBP and DBP were independent determinants of AI response to Iso (r = 0.78, P < 0.0001).

Conclusions: Our findings show that AI and PP fail as surrogate measures of arterial stiffness during beta-adrenergic stimulation.

PubMed Disclaimer

Comment in

Publication types