Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Apr 27;109(16):1942-7.
doi: 10.1161/01.CIR.0000127110.49192.72. Epub 2004 Apr 12.

One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial

Affiliations
Clinical Trial

One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial

Gregg W Stone et al. Circulation. .

Abstract

Background: The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown.

Methods and results: In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were prospectively randomized to the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or an identical-appearing bare-metal EXPRESS stent. By actuarial analysis, the TAXUS stent compared with the bare-metal stent reduced the 12-month rates of target-lesion revascularization by 73% (4.4% versus 15.1%, P<0.0001), target-vessel revascularization by 62% (7.1% versus 17.1%, P<0.0001), target-vessel failure by 52% (10.0% versus 19.4%, P<0.0001), and composite major adverse cardiac events by 49% (10.8% versus 20.0%, P<0.0001). The 1-year rates of cardiac death (1.4% versus 1.3%), myocardial infarction (3.5% versus 4.7%), and subacute thrombosis (0.6% versus 0.8%) were similar between the paclitaxel-eluting and control stents, respectively. Between 9 and 12 months, there were significantly fewer myocardial infarctions (0% versus 1.1%, P=0.007), target-vessel revascularizations (2.4% versus 5.8%, P=0.002), and major adverse cardiac events (2.4% versus 6.3%, P=0.0009) in the paclitaxel-eluting stent than in the control stent group, respectively.

Conclusions: The relative efficacy reported at 9 months for the polymer-based, paclitaxel-eluting TAXUS stent compared with the EXPRESS stent is preserved and continues to increase at 1 year, with no safety concerns apparent.

PubMed Disclaimer

Comment in

LinkOut - more resources