Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Mar;34(3):118-23.
doi: 10.1093/jjco/hyh025.

Magnetic anchor for more effective endoscopic mucosal resection

Affiliations

Magnetic anchor for more effective endoscopic mucosal resection

Toshiaki Kobayashi et al. Jpn J Clin Oncol. 2004 Mar.

Abstract

Background: Technical difficulties are involved in endoscopic mucosal resection (EMR) of gastric cancer since it is a "one handed surgery". These difficulties prevent this technique from being indicated for larger lesions, even when it can possibly be performed for patients with such lesions. If microforceps could assist EMR, this procedure would become easier and safer. Since magnetic force can control objects without direct contact, it can be applied to control microforceps internally in assistance with EMR.

Methods: We developed a magnetic anchor consisting of three parts: a magnetic weight with dimensions of 1.0 x 1.0 x 1.5 cm, microforceps and a connecting thread. Endoscopic clips used in hemostasis were used as the microforceps of the magnetic anchor in this study. The magnetic control system consisted of a 0.68 kOe/10 cm/100 A electromagnet, 350 mm in diameter and a circumventing positional frame. The microforceps were inserted into a sheath within the endoscope, and the magnetic weight was secured to the tip of the sheath protruding from the endoscope. The magnetic anchor, along with the endoscope, was inserted through an overtube into the gastric cavity of a swine under general anesthesia. The magnetic anchor was used in a manner similar to that in standard surgery, and EMR was thereby performed.

Results: The mucosa to be resected was satisfactorily dragged and stabilized. The magnetic anchor facilitated EMR, regardless of the technical skills of the endoscopist and region of the stomach at which the technique was performed.

Conclusion: The magnetic anchor is considered to have alleviated some technical problems involved in EMR. It has the potential for making EMR a safer and quicker procedure for the treatment of early gastric cancer, when appropriately indicated.

PubMed Disclaimer

Publication types

LinkOut - more resources